| Size: | |
|---|---|
| Availability: | |
| Quantity: | |
Ball Valve
J-VALVES
2000WOG Forged Steel A105N SS316 1PC Hex Ball Valve Thread End
Design Features
Material:
Valve Body: ASTM A105N carbon steel, which is suitable for high-pressure environments.
Valve Internals: Stainless steel 316, with good corrosion resistance and mechanical properties.
Connection Method: Threaded connection, which complies with ANSI B1.20.1 standard, ensuring a reliable connection between the valve and the piping system.
Operation Mode: Manually operated and equipped with a handwheel, it is suitable for on-site manual control.
Floating Ball Design: The ball can float freely under the action of fluid pressure, ensuring sealing performance and reducing operating torque at the same time.
Fireproof Design: It complies with the API 607 fire safety standard, ensuring the sealing performance of the valve under fire conditions.
Anti-static Device: Equipped with an anti-static device to prevent electrostatic accumulation, it is suitable for flammable and explosive media.
Anti-blowout Stem: The stem design complies with the API 607 standard, and can prevent the stem from being blown out even under high-pressure conditions.
Sealing Materials: The valve seat uses PTFE or other high-performance sealing materials, which are suitable for a variety of media and temperature ranges.
Technical Parameters
Nominal Diameter: 1/2" ~ 2" (DN15 ~ DN50)
Pressure Rating: 2000WOG
Applicable Media: Water, natural gas, petroleum, steam, etc.
Applicable Temperature: -20℃ ~ 180℃
Valve Body Material: ASTM A105N
Valve Internals Material: Stainless steel 316
Sealing Materials: PTFE, PEEK, etc.
Connection Method: Threaded connection (NPT, BSPT, BSPP, DIN259/2999)
Operation Method: Manual
Design Standards: API 608, ASME B16.34
Testing Standards: API 598
Application Fields
Petroleum and Natural Gas Industry: Used in the transportation, storage, and processing systems of petroleum and natural gas.
Chemical Industry: Used to control the flow of corrosive media.
Water Treatment Industry: Used in the water transportation and treatment systems.
Energy Industry: Used in the cooling water systems and steam systems of power plants.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.