| Availability: | |
|---|---|
| Quantity: | |
Stainless Steel Y-Type Screwed Strainer
Technical Specifications
Size Range: 1/2" ~ 24" (DN15 ~ DN600)
Connection Method: Threaded connection (NPT, BSPT, BSPP, etc.)
Material: 304 or 316 stainless steel
Filter Screen Specification: Usually a 316 stainless steel filter screen with a pore diameter of 1mm and a spacing of 2mm.
Working Temperature Range: -20°C ~ 180°C.
Working Pressure: Up to 200 psi.
Standards: ISO, ANSI, etc.
Product Features
Efficient Filtration: It adopts a precision stainless steel filter screen, which can effectively remove impurities and solid particles in the fluid.
Easy to Clean and Maintain: Equipped with a detachable drain port, it is convenient for regular cleaning of impurities without interrupting the operation of the pipeline.
Strong Corrosion Resistance: The 316 stainless steel material enables it to resist the corrosion of various chemical media.
Flexible Installation: It can be installed horizontally or vertically to adapt to various pipeline layouts.
Compact Design: It is small in size and space-saving, suitable for installation in narrow pipeline systems.
Application Areas
The stainless steel threaded Y-type filter is applicable to the following fields:
Water Treatment Systems: Filter impurities in water to protect pumps and pipeline systems.
Petrochemical Industry: Remove solid particles in oil products and chemical media to prevent equipment blockage.
Food Processing and Pharmaceutical Industries: Ensure the purity of the fluid and meet strict hygiene requirements.
HVAC Systems: Filter impurities in the cooling liquid to protect heat exchangers and other equipment.
Natural Gas and Steam Systems: Remove impurities in gas or steam to ensure the safe operation of the systems.
Installation and Maintenance
Before Installation: Check whether the inside of the filter is clean and make sure there is no impurity blocking the filter screen. Check whether the threaded connection is intact, without damage or burrs.
During Installation: Pay attention to the fluid flow direction mark and make sure the fluid flow direction is consistent with the mark. When installing, tighten the threads, but avoid excessive force that may cause damage.
Maintenance: Regularly check the sealing performance of the filter and the integrity of the filter screen. If there is any abnormality, clean or replace the filter screen in time.
Advantages
High-Quality Manufacturing: All products have undergone strict testing and comply with international standards.
Customization Service: Filters with different sizes, materials and connection methods can be provided according to customer needs.
Quick Response: Suppliers can usually provide technical support and product supply within a short time.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.