| Availability: | |
|---|---|
| Quantity: | |
Structural Features
Carbon Steel Material: The valve body is made of ASTM A216 WCB carbon steel, which offers high strength and good corrosion resistance, suitable for various media and working conditions.
Flanged Connection: Both ends adopt a flanged connection method that complies with GOST standards, ensuring easy installation and tight sealing.
Compact Design: With a small size and light weight, it is easy to install and maintain, making it particularly suitable for occasions with limited space.
Reliable Sealing: The valve disc and valve seat undergo precision machining to ensure good sealing performance and prevent medium leakage.
Multiple Operation Modes: Handwheel operation is provided, which is easy to operate and suitable for manual control. Gear, pneumatic, or electric actuators can also be optionally equipped to achieve automatic control.
Fire Safety Design: Compliant with API 607 and API 6FA standards, the valve can maintain sealing performance even in case of fire, safeguarding the safety of personnel and equipment.
Anti-Static Device: A built-in anti-static device ensures electrical continuity, prevents static accumulation, and reduces the risk of fire and explosion.
Technical Parameters
Nominal Diameter: DN200
Pressure Class: PN25
Temperature Range: -29℃ to +425℃
Materials:
Valve Body: ASTM A216 WCB
Valve Disc: 304 Stainless Steel
Valve Stem: 304 Stainless Steel
Sealing Ring: Nitrile Butadiene Rubber (NBR) or Polytetrafluoroethylene (PTFE)
Connection Method: Flanged Connection (RF), compliant with GOST standards
Design Standard: GOST
Testing Standards: API 598, ISO 5208
Face-to-Face Dimensions: Compliant with GOST standards
Application Fields
Oil and Natural Gas Industry: Used in oil and gas field exploration, gathering, transportation, and processing systems to control the flow direction of fluids and ensure the smooth progress of the production process.
Chemical Industry: Suitable for the transportation and reaction systems of various chemical media, preventing medium leakage and ensuring production safety.
Water Treatment Industry: Applied in the water supply and drainage systems of water plants and sewage treatment plants to control the on-off and flow direction of water, improving water treatment efficiency and water quality safety.
Food and Beverage Industry: Meets food-grade requirements and is used in pipeline systems during food and beverage production to ensure hygiene and safety.
HVAC: Used in cooling water systems, hot water systems, etc., to control the on-off and flow direction of water, ensuring the efficient operation of the system.
General Industrial Applications: Suitable for the control and isolation of media such as water, oil, and gas, ensuring the safe and efficient operation of the system.
Advantages and Value
High Reliability: The carbon steel material and compact design ensure the valve operates stably in high-pressure and high-temperature environments, reducing maintenance frequency and downtime.
High Safety: The fire protection, anti-static design, and reliable sealing performance effectively reduce the risk of leakage, safeguarding the safety of personnel and equipment.
Easy Operation: The handwheel operation mode provides a stable and labor-saving operation experience, suitable for manual control. Automatic actuators can also be optionally equipped to achieve remote control.
Convenient Installation and Maintenance: The flanged connection simplifies the installation process and also facilitates maintenance and overhaul, reducing maintenance costs.
Wide Applicability: Multiple material options and a broad range of pressure and temperature make it adaptable to various complex working conditions and medium characteristics.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.