| Availability: | |
|---|---|
| Quantity: | |
Stainless Steel Threaded Gate Valve
Technical Specifications
Size: 1/4" ~ 4" (DN6~DN100)
Pressure Rating: 150LB~2500LB (PN20~PN420)
Temperature Range: -20°C ~ 200°C
Connection Method: Threaded connection (NPT or other standard threads)
Valve Body Material: 316 stainless steel
Valve Disc Type: Wedge Disc
Operation Mode: Manual operation (non-rising stem)
Sealing Material: PTFE or other high-performance sealing materials
Testing Standard: API 598
Product Features
Strong Corrosion Resistance: Made of 316 stainless steel, it can resist the corrosion of various chemical media.
Reliable Sealing Performance: With PTFE sealing materials, it ensures zero leakage of the valve even under high pressure.
Convenient Installation: The threaded connection method simplifies the installation and disassembly process and is suitable for various pipeline layouts.
Easy Operation: Manual operation mode requires no external power and is suitable for on-site manual control.
Wide Application Range: Applicable to various media such as water, oil, steam, natural gas, etc., and suitable for multiple industrial environments.
Application Areas
Petrochemical Industry: Used for transporting oil products, chemicals and other media to prevent leakage and pollution.
Water Treatment System: Used to control the water flow and ensure the stability of water quality and flow rate.
Natural Gas System: Used in natural gas transmission pipelines to ensure the safe transmission of gas.
Food Processing Industry: Meeting the hygiene requirements, it is used in the production process of food and beverages.
HVAC System: Used in hot water and cold water circulation systems to control the flow rate and pressure.
Installation and Maintenance
Before Installation: Check whether the inside of the valve is clean and make sure there is no impurity blocking the valve disc. Check whether the threaded connection is intact, without damage or burrs.
During Installation: Pay attention to the flow direction mark on the valve and make sure the fluid flow direction is consistent with the mark. When installing, tighten the threads, but avoid excessive force that may cause damage.
Maintenance: Regularly check the sealing performance of the valve and the flexibility of the valve disc. If there is any abnormality, repair or replace the components in time.
Advantages
High-Quality Manufacturing: All products of J-VALVES have undergone 100% factory testing and comply with international standards such as API 600 and ASME B16.34.
Customization Service: Customized design and manufacturing services can be provided according to customer needs.
Quick Response: All inquiries will be replied within 48 hours to ensure that customers can obtain support in a timely manner.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.