| Availability: | |
|---|---|
| Quantity: | |
J-VALVES-CV
J-VALVES
8481804090
Product Features
High-quality Materials: The valve body and disc are made of 316 stainless steel (CF8M), featuring high strength and excellent corrosion resistance to adapt to various complex working environments.
Flange Connection: Adopts ANSI Class 150 standard flange connections to ensure quick and reliable integration with pipeline systems, facilitating installation and maintenance.
Swing Design: The unique swing design allows the disc to swing freely, ensuring unidirectional medium flow and preventing backflow.
Superior Sealing Performance: Uses high-quality sealing materials (e.g., PTFE and graphite) to maintain excellent sealing under all operating conditions.
Convenient Operation: No external power is required; it automatically opens and closes by the medium’s own pressure, offering simple and reliable operation.
Fire-safe Design: Complies with API 607 fire safety standards, suitable for high-risk environments.
Anti-static Design: Equipped with anti-static devices to ensure safety in flammable and explosive environments.
Multiple Standards Compliance: Meets international standards such as API 6D and ASME B16.34, guaranteeing product quality and performance reliability.
Technical Parameters
Nominal Pressure: ANSI Class 150
Size Range: 2" (DN50)
Operating Temperature: -29°C to 300°C
Applicable Media: Water, natural gas, oil, air, acidic liquids, etc.
Valve Body Material: 316 stainless steel (CF8M)
Valve Disc Material: 316 stainless steel (CF8M)
Sealing Material: PTFE, graphite, etc.
Connection Method: Flange connection (ANSI B16.5)
Design Standards: API 6D, ASME B16.34
Inspection & Testing: API 598
Sealing Class: ANSI B16.104 Class VI
Application Areas
This valve is widely used in:
Petroleum and Natural Gas: Fluid control in oil extraction, transportation, and refining.
Chemical Industry: Handling corrosive chemicals to ensure system safety and stability.
Water Treatment Systems: Controlling water flow to ensure water quality and system reliability.
Pharmaceutical Industry: Fluid control in pharmaceutical production to ensure media hygiene and safety.
Food Industry: Fluid control in food processing to ensure media hygiene and safety.
HVAC: Central air conditioning systems, hot water supply systems, etc., to ensure efficient operation.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.