| Availability: | |
|---|---|
| Quantity: | |
Product Features
High-Quality Material: The valve body is made of carbon steel (GS-C25), featuring high strength and good corrosion resistance, making it adaptable to various complex working conditions.
Flange Connection Design: Adopting DIN-standard flange connection, it ensures seamless docking with pipeline systems, featuring convenient installation and reliable sealing performance.
Reliable Sealing Performance: The valve seat uses a metal seal, ensuring zero-leakage sealing performance under high-pressure and high-temperature conditions.
Compact Design: With a compact structure, small volume, and lightweight, it is easy to install and maintain, especially suitable for pipeline systems with limited space.
Fire-Safe Design: Compliant with the API 607 fire safety standard, it can maintain sealing performance even under extreme conditions such as fires, ensuring system safety.
Multiple Operation Modes: Manual operation or being equipped with an actuator for automatic control is optional, meeting the needs of different application scenarios.
Low Flow Resistance Design: The internal flow channel of the valve body is smooth with low flow resistance, which can effectively reduce energy consumption and improve system efficiency.
Technical Specifications
Nominal Diameter: 1/2"~48" (DN15~DN1200)
Nominal Pressure: 150LB~2500LB
Operating Temperature: -29℃ to 425℃, depending on the sealing material
Valve Body Material: Carbon steel (GS-C25)
Sealing Material: Metal seal (PTFE or other high-performance sealing materials are optional)
Connection Type: Flange connection (DIN standard)
Operation Mode: Manual operation, pneumatic operation, electric operation (optional)
Design Standards: DIN 3352, DIN 3202
Testing Standards: API 598, DIN 3230
Application Fields
Oil and Gas: Used in high-pressure oil and gas transmission pipelines, refineries, and natural gas processing facilities.
Chemical Industry: Suitable for handling corrosive chemical media such as acids, alkalis, and salt solutions.
Water Treatment and Municipal Water Supply: Ensures water quality safety and stable operation of the system.
Paper Industry: Used for handling slurries containing suspended particles.
Marine Engineering: Performs well in seawater environments, suitable for fluid control systems on offshore platforms and ships.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.