| Availability: | |
|---|---|
| Quantity: | |
Cast Steel Double Disc Dual Plate/Flap/Butterfly Wafer Check Valve
Technical Specifications
Size Range: 2" ~ 84" (DN50 ~ DN2100)
Pressure Rating: 150LB ~ 2500LB (PN20 ~ PN420)
Materials:
Valve Body: A216 WCB, 304, 316
Valve Disc: 304, 316, AL Bronze
Sealing Material: EPDM, NBR, Viton
Applicable Temperature: -20°C ~ 200°C
Applicable Media: Water, oil, natural gas, steam, seawater, etc.
Connection Method: Wafer Type, which can be installed between flanges.
Design Standards: API 594, DIN 3202, ANSI B16.34.
Testing Standards: API 598.
Product Features
Double-Disc Design: It adopts two semi-circular valve discs, which can open quickly when the fluid flows forward and close automatically when the fluid flows backward.
Wafer Connection: It has a compact structure, is easy to install and saves space.
Low Pressure Loss: With a reasonable flow channel design, it has low fluid resistance and low pressure loss.
Good Sealing Performance: It uses rubber or metal seals to ensure zero leakage.
Fireproof Design: It complies with the API 607 standard, ensuring that it can still maintain sealing in the event of a fire.
Strong Corrosion Resistance: The cast steel or stainless steel material enables it to resist the corrosion of various chemical media.
Lightweight Design: Compared with traditional flange check valves, it is lighter in weight and convenient for installation and maintenance.
Application Areas
Petrochemical Industry: Used to prevent the backflow of fluids in oil and gas transmission pipelines.
Water Treatment Systems: Used to prevent the backflow of water and protect pumps and pipeline systems.
Natural Gas Systems: Used in natural gas transmission pipelines to ensure the safe transmission of gas.
Offshore Engineering: Used in seawater pipeline systems to prevent the backflow of seawater.
Pharmaceutical and Food Industries: Used to handle corrosive media such as acids and alkalis and ensure aseptic processes.
HVAC: Used for the flow regulation at the inlets and outlets of hot and cold water systems and heat exchangers.
Installation and Maintenance
Before Installation: Check whether the inside of the valve is clean and make sure there is no impurity blocking the valve disc. Check whether the flange connections are intact.
During Installation: Ensure that the fluid flow direction is consistent with the arrow mark on the valve body. When using the wafer connection method, make sure that the pipeline flanges are aligned with the valve and tighten the bolts evenly.
Maintenance: Regularly check the sealing performance. If there is leakage, replace the sealing parts in time. Regularly clean the impurities inside the valve body to ensure the normal operation of the valve.
Advantages
High-Quality Manufacturing: Manufactured strictly in accordance with international standards to ensure product quality and performance.
Customization Service: Valves with different sizes, materials and connection methods can be provided according to customer needs.
Wide Application: Applicable to various media and working conditions to meet the needs of different industries.
Automation Compatibility: Actuators can be optionally equipped to achieve automated control.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.