| Availability: | |
|---|---|
| Quantity: | |
Main Features
Material and Structure:
Valve Body Material: Made of bronze C95800, which has good corrosion resistance and mechanical strength, suitable for various media.
Flange Connection: RF (Raised Face) flange connection complying with ASME B16.5 standard ensures reliability and sealing performance with pipeline systems.
Y-type Design: The unique Y-type structure facilitates impurity deposition and cleaning, reducing pressure drop.
Filtration Performance:
Filter Screen Material: Stainless steel 304 or 316, with strong corrosion resistance and long service life.
Filtration Precision: 20 mesh (MESH 20), which can effectively remove solid impurities in the fluid and protect downstream equipment.
Easy Cleaning: The filter bottom is equipped with a drain port for convenient regular cleaning of impurities, featuring simple maintenance.
Operational Performance:
Pressure Class: 150LB, suitable for medium-pressure working conditions.
Working Temperature: -20°C to 150°C, suitable for various temperature environments.
Quick Disassembly: The flange connection facilitates quick disassembly and maintenance, reducing maintenance costs.
Application Scope:
Working Temperature: -20°C to 150°C.
Applicable Media: Water, natural gas, oil, corrosive liquids, etc.
Pressure Class: 150LB, meeting medium-pressure requirements.
Technical Specifications
Size Range: 1" to 12" (DN25 to DN300).
Pressure Class: 150LB.
Working Temperature: -20°C to 150°C.
Applicable Media: Water, natural gas, oil, corrosive liquids.
Screen Precision: 20 mesh (MESH 20).
Design and Manufacturing Standards: ANSI B16.34, API 600.
Inspection and Testing Standard: API 598.
Materials:
Valve Body: Bronze C95800.
Filter Screen: Stainless steel 304 or 316.
Flange: Complying with ASME B16.5 standard.
Application Scenarios
Petroleum and Natural Gas Industry: Used in natural gas pipelines and oil transportation systems to remove solid impurities from fluids and protect downstream equipment.
Chemical Industry: Suitable for handling corrosive chemical media such as sulfuric acid and phosphoric acid.
Water Treatment Industry: Used in urban water supply and sewage treatment systems to ensure water quality cleanliness.
Mining and Metallurgy: Used in high-wear material transportation systems to protect pipelines and equipment.
Food Processing Industry: Used in food processing equipment to ensure hygiene and cleanliness.
Pharmaceutical Industry: Used for fluid control requiring high hygiene standards.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.