| Availability: | |
|---|---|
| Quantity: | |
J-VALVES-BV-1000
J-VALVES
8481804090
Product Features
High-quality Materials: The valve body is made of duplex stainless steel F51, which features high strength and excellent corrosion resistance, enabling it to adapt to a wide variety of complex working environments.
Three-piece Structure: With a three-piece design, it is convenient for the maintenance and replacement of internal parts. There is no need to disassemble the entire valve, saving both time and cost.
Threaded Connection: The threaded connection method ensures a quick and reliable connection between the valve and the pipeline system, making installation and maintenance convenient.
Convenient Operation: Equipped with a handle operation mechanism, it allows for flexible and convenient operation, enabling precise control.
Fire-safe Design: Compliant with API 607 fire-safe standards, it is suitable for high-risk environments.
Anti-static Design: Equipped with an anti-static device, it ensures safety in flammable and explosive environments.
Compliance with Multiple Standards: It complies with international standards such as API 6D, API 608, and ASME B16.34, ensuring the reliability of product quality and performance.
Technical Parameters
Nominal Pressure: 1000 PSI
Size Range: 1/2 inch - 6 inch (DN15 - DN150)
Operating Temperature: -29°C to 200°C
Applicable Media: Natural gas, petroleum gas, air, water, acidic liquids, etc.
Valve Body Material: Duplex stainless steel F51 (ASTM A182 F51)
Valve Disc Material: Duplex stainless steel F51
Valve Seat Material: PTFE, nylon, etc.
Connection Method: Threaded connection (NPT)
Operation Method: Manual
Design Standards: API 6D, API 608, ASME B16.34
Inspection and Testing: API 598
Sealing Class: ANSI B16.104 Class VI
Application Areas
This valve is widely used in the following fields:
Petroleum and Natural Gas: Used for fluid control in the processes of oil extraction, transportation, and refining.
Chemical Industry: Used for handling corrosive chemicals to ensure the safety and stability of the system.
Water Treatment Systems: Used for controlling the flow of water to ensure water quality and the reliability of the system.
Pharmaceutical Industry: Used for fluid control in the pharmaceutical production process to ensure the hygiene and safety of the media.
Food Industry: Used for fluid control in the food processing process to ensure the hygiene and safety of the media.
HVAC: Used in central air conditioning systems, hot water supply systems, etc., to ensure the efficient operation of the systems.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.