Forged Steel Flanged Metal Seal Trunnion Mounted Ball Valves
Main Features
Stem Design: The valve stem is supported by bearings, which reduces the operating torque and improves the stability and reliability of the valve. It is especially suitable for large-diameter and high-pressure working conditions.
Metal Sealing: Metal-to-metal sealing is adopted, which has higher wear resistance and high-temperature resistance, and is suitable for handling highly corrosive media.
Three-piece Body: The valve body is divided into three parts, which is convenient for assembly and maintenance, and at the same time ensures the overall strength and sealing performance of the valve.
Fire Safety Design: It complies with the API 607 fire safety standard and can maintain its sealing performance in extreme situations such as fires.
Anti-static Device: It has a built-in anti-static device to ensure electrical continuity among the valve stem, ball, and valve body, reducing the safety risks caused by static electricity.
Anti-blowout Valve Stem Design: The valve stem design includes a protective sleeve to prevent the valve stem from being blown out under high pressure.
Emergency Sealing Injection System: When the soft sealing material is damaged due to fire or other accidents, a sealant can be injected through the sealant injection device to provide additional sealing guarantee.
Multiple Connection Methods: It provides various end connection methods such as flange connection and butt welding connection to meet different installation requirements.
Technical Specifications
Size Range: 1/2"~56" (DN15~DN1400)
Pressure Rating: 150LB~2500LB (PN20~PN420)
Applicable Temperature: -46℃~425℃.
Applicable Medium: Water, gas, oil, corrosive chemicals, etc.
Materials:
Valve Body: A105 forged steel
Seat: Metal seal
Stem: A105 forged steel
Design Standards:
Design: API 6D, ASME B16.34
Flange Connection: ASME B16.5
Butt Welding Connection: ASME B16.25
Testing: API 598, API 6D
Fire Safety Testing: API 607, API 6FA.
Operation Modes: Manual (handwheel, gear), pneumatic, electric, etc.
Application Fields
Petroleum and Natural Gas Industry: Used for oil and gas transportation, wellhead isolation, pressure testing, etc., and it is especially suitable for occasions requiring high reliability and fire safety.
Chemical Industry: Used to handle highly reactive chemicals to ensure process safety.
Power Industry: Used for medium isolation in high-pressure systems, such as boilers and turbines.
Municipal Engineering: Used in water supply and drainage systems to ensure water quality safety and pipeline maintenance.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.