| Availability: | |
|---|---|
| Quantity: | |
2“-48”
J-VALVES
Stainless Steel CF8M Trunnion Mounted Ball Valve with ISO5211 Mounting Platform
Stainless steel CF8M trunnion mounted ball valve with ISO5211 mounting platform, Split-Body full port flanged end ball valves employ investment or shell cast bodies & tailpieces, all produced from ASTM grade materials that are properly heat treated and chemically finished. All wall thicknesses comply with ASME B16.34 as do bolting stress levels.
Industrial and Oil/Gas piping applications requiring the higher flow capacity and lower pressure drop of full port internal flow-ways, and those applications where ease of repairability is desired.
Stainless steel CF8M trunnion mounted ball valve with ISO5211 mounting platform,trunnion ball valve are designed, constructed, and tested according to API and ASME/ANSI Standards. Other international standards including BS and DIN are also available upon request.
1.Stainless Steel CF8M Trunnion Mounted Ball Valve with ISO5211 Mounting Platform Technical specifications:
3-Piece Bolted Body, Full Port Construction
Fully Compliant to ASME B16.34 ,API6D ,BS5351
Fully Compliant to API 608
API 607 6th Edition Fire-Safe
All Models are NACE MR0175 Compliant
Submerged Packing System & Direct Mount Actuation
Standard ISO Actuator Mounting Pads on All Sizes
Second Generation PTFE Seats Provide Higher Operating Temperatures
Standard Electrically Grounded Ball & Stem
2.Stainless Steel CF8M Trunnion Mounted Ball Valve with ISO5211 Mounting Platform Product Specification:
Size: 1/2''-48''(DN15~DN1200)
Pressure Rating: 150LB-2500LB(PN20~PN420)
Material: A351 CF8M/CF8/CF3/CF3M, A216 WCB, A352 LCB/LCC,A105N,F51/F53/F304/F316/F316L
Suitable Temperature: -196ºC~450ºC( Different temperature choose different materials).
Suitable Medium: Water, Steam, Oil and natural gas etc.
3.Stainless Steel CF8M Trunnion Mounted Ball Valve with ISO5211 Mounting Platform Product Feature:
Floating ball, full bore or reduce bore.
ISO5211 mounting pad for option.
Blow-out proof stem design.
PTFE/RPTFE seat seal( Seat seal material could be decided by customer's request or according to valve's medium & temp. condition).
Anti-static design and API 607 Fire Safe Design available.
Operation: Hand wheel, Worm wheel, Pneumatic actuator & Electric Actuator.
Note: All the data should be confirmed with the approved drawings of manufacturer.
Application & Function:
Stainless steel CF8M trunnion mounted ball valve with ISO5211 mounting platform are suitable to stand the harsh service conditions often present in industrial and petroleum industry. These valves are recommended for tight shut-off in high pressure and arduous fluid applications.
Stainless steel CF8M trunnion mounted ball valve designed the Side-Entry Trunnion-Mounted Ball Valves to assure bi-directional sealing of the valve with two independent floating seats. The design of these seats minimizes the torque required to operate the valve without losing the sealing power. This power is assured by zero differential pressure to the valve’s maximum rated pressure. In addition, these repairable valves are manufactured to seal off both seats at the same time and to allow bleeding of the entrapped cavity pressure (DBB) with the ball in the closed position. The DBB feature allows for verifying that the seats are properly sealing.
Tips:
We also manufacture other type valves, as butterfly valve, check valve, globe valve, Y strainer, sanitary butterfly valve, sanitary ball and so on.
Any item meets your interest, anything confused you, pls keep me posted, let's talk more.
J-VALVES Service:
On Samples Buyer bear the air fee, but this fee will be reduced from order directly
On After Sales Free replacement if there is any quality problem
On Delivery Never delay delivery time
On Materials Ensure material pure
Ensure material pure
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.
ISO 5208 Rates A-G explained with real numbers, how API 598, API 6D and FCI 70-2 map across, and what metal seats can honestly achieve.
How to choose a forged or cast valve body: API 600 vs API 602 size limits, casting quality factor, NDT coverage, weld repair policy and cost crossovers.
How pressure seal bonnet valves work, why bolted bonnets stop at Class 900, seal ring materials, disassembly rules and the low-pressure leak signature.