API6D Full Bore Forged Steel A105 Flanged Type Trunnion Ball Valves
Technical Parameters
Size Range: 1/2"~56" (DN15 ~ DN1400)
Pressure Rating: 150LB~2500LB (PN20~PN420)
Materials:
Valve Body: A105 forged steel
Ball: Usually stainless steel
Sealing Surface: PTFE, RPTFE or metal seal
Applicable Temperature: -46℃ - 220℃
Applicable Media: Water, steam, oil, natural gas, corrosive chemicals, etc.
Design and Manufacturing Standards: API 6D, API 608, BS 5351
Pressure and Temperature Standard: ASME B16.34
Face-to-Face Dimension Standard: ASME B16.10
Flange Standard: ASME B16.5, ASME B16.47
Testing and Inspection Standard: API 598, API 6D
Fire Safety Standard: API 607
Operation Modes: Manual (handwheel), worm gear, pneumatic actuator, electric actuator
Product Features
Full Bore Design: It provides higher flow capacity and lower pressure drop, and is suitable for various industrial and oil and gas pipeline applications.
Trunnion Support Design: It enhances the stability of the valve, reduces the operating torque, and improves the service life.
Fire Safety: It complies with the API 607 fire safety standard and is suitable for flammable and explosive environments.
Anti-static Design: It effectively prevents the accumulation of static electricity and avoids potential safety hazards caused by static electricity.
Multiple Sealing Materials Available: Select appropriate sealing materials according to the medium and temperature conditions to ensure stable sealing performance.
Multiple Drive Modes: Various drive modes such as manual, worm gear, pneumatic, and electric are available to meet different operation requirements.
Compatibility with International Standards: It complies with international standards such as API 6D and ASME B16.34 to ensure product quality and reliability.
Corrosion-resistant Design: Made of A105 forged steel, it has excellent corrosion resistance and is suitable for various harsh working conditions.
Application Scenarios
Petroleum and Natural Gas Industry: Used in oil and gas transportation pipelines to ensure safe and efficient operation.
Chemical Industry: Used to control the transportation and distribution of corrosive chemicals.
Water Treatment Industry: Used in water and wastewater treatment systems to control the water flow.
Power Industry: Used in the cooling water system and steam system of power plants.
Shipbuilding Industry: Used in the seawater and freshwater systems of ships.
In a soft seat butterfly valve the rubber liner is the seat, the flange gasket and the temperature limit. How it seals, how it fails, what to specify.
A bellows seal gate valve replaces the stuffing box with a welded metal bellows. Why the stem stops turning, what the tell-tale port shows, when packing wins.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.