| Availability: | |
|---|---|
| Quantity: | |
DIN Standard CF3M PN16/PN25 Stainless Steel Flange End Swing Check Valve
Design Features
Swing Type Structure: The valve disc rotates around the axis of the valve seat, with quick opening and closing actions, low fluid resistance, and can effectively prevent the backflow of media.
Full Bore Design: The passage inside the valve body is consistent with the inner diameter of the pipeline, ensuring the smooth flow of media, reducing pressure loss, and improving the overall efficiency of the system.
Strong Corrosion Resistance: The stainless steel of CF3M material has excellent anti-corrosion performance, can resist the erosion of various chemical media, extend the service life of the valve, and reduce maintenance costs.
Flange Connection: The flange connection method conforming to the DIN standard is adopted, making installation and maintenance more convenient and ensuring a reliable connection between the valve and the piping system.
Compliance with International Standards: Its design and manufacture comply with standards such as DIN 3357 and DIN 3202, ensuring the quality and reliability of the product and meeting the engineering specification requirements of different countries and regions.
Technical Parameters
Nominal Diameter: DN15 - DN600
Pressure Rating: PN16, PN25
Applicable Temperature: -29℃ ~ 300℃
Applicable Media: Non-corrosive and weakly corrosive media such as water, oil, natural gas, and steam.
Connection Method: Flange connection
Design Standard: DIN 3357
Face-to-Face Dimension Standard: DIN 3202-F1
Testing Standard: EN 12266-1/2
Application Fields
This valve is widely used in the piping systems of industries such as petroleum, chemical engineering, natural gas, water treatment, shipbuilding, and offshore engineering to prevent the backflow of media, ensure the one-way flow of fluids, and guarantee the safe operation of the system. For example, it prevents the backflow of oil products in petroleum transmission pipelines and controls the flow direction of corrosive media in the chemical production process.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.