| Availability: | |
|---|---|
| Quantity: | |
DIN PN16 CF8 Stainless steel Flanged Gate Valve
Technical Parameters
Nominal diameter: 1/2" ~ 48" (DN15 ~ DN1200)
Pressure rating: 150LB ~ 2500LB (PN20 ~ PN420)
Applicable temperature: -20℃ ~ 300℃
Applicable media: water, steam, oil products, natural gas, acid gases, etc.
Materials:
Valve body: CF8
Valve cover: CF8
Valve disc: CF8
Valve stem: 304 or 316 stainless steel
Sealing surface: Stainless steel or hard alloy
Connection method: Flanged connection
Operation mode: Manual (handwheel operation), with optional electric or pneumatic actuators
Design standard: DIN 3352
Structural length: In accordance with the DIN 3202 standard
Testing standard: EN 12266-1
Product Features
Strong corrosion resistance: The CF8 material has excellent corrosion resistance and is suitable for a variety of corrosive media.
Reliable sealing: Adopting a wedge-shaped valve disc design, it has reliable sealing performance and a long service life.
Flanged connection: Conforming to the DIN 2501 standard, it is convenient for installation and has good sealing performance.
Easy operation: Equipped with a handwheel operating mechanism, it can be opened and closed quickly and operated flexibly.
Multiple options: Electric or pneumatic actuators can be equipped according to customer needs to achieve automated control.
Standards compliance: The design and manufacturing comply with the DIN standard, and the testing complies with relevant standards.
Application Areas
Petroleum and natural gas industry: Used in oil and gas transmission pipelines to control the flow of media such as oil and natural gas.
Chemical industry: Suitable for the control of corrosive media in chemical production.
Water treatment industry: Used in water supply and drainage systems to control the opening and closing of water flow.
Energy industry: In the cooling water system and steam system of power stations, it ensures the reliable transmission of media.
Food and pharmaceutical industries: Suitable for the control of clean fluids in the food and pharmaceutical industries.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.