| Size: | |
|---|---|
| pressure: | |
| Availability: | |
| Quantity: | |
2inch 150lb A351 CF8 Stainless Steel Flange Globe Valve
Technical Parameters
Nominal diameter: 1/2" ~ 36" (DN15 ~ DN900)
Pressure rating: 150LB ~ 2500LB (PN20 ~ PN420)
Applicable temperature: -20℃ ~ 300℃
Applicable media: water, steam, oil products, natural gas, acid gases, etc.
Materials:
Valve body: A351 CF8
Valve cover: A351 CF8
Valve disc: A351 CF8
Valve stem: 304 or 316 stainless steel
Sealing surface: Stainless steel or hard alloy
Connection method: Flanged connection, in compliance with ANSI B16.5 standard
Operation mode: Manual, with optional electric or pneumatic actuators
Design standard: API 600, ANSI B16.34
Structural length: In accordance with ASME B16.10 standard
Testing standard: API 598
Product Features
Strong corrosion resistance: The A351 CF8 material has excellent corrosion resistance and is suitable for a variety of corrosive media.
Reliable sealing: Adopting a wedge-shaped valve disc design, it has reliable sealing performance and a long service life.
Flanged connection: In compliance with ANSI B16.5 standard, it is convenient for installation and has good sealing performance.
Easy operation: Equipped with a handwheel operating mechanism, it can be opened and closed quickly and operated flexibly.
Multiple options: Electric or pneumatic actuators can be equipped according to customer needs to achieve automated control.
Standards compliance: The design and manufacturing comply with API 600 and ANSI B16.34 standards, and the testing complies with API 598 standard.
Application Areas
Petroleum and natural gas industry: Used in oil and gas transmission pipelines to control the flow of media such as oil and natural gas.
Chemical industry: Suitable for the control of corrosive media in chemical production.
Water treatment industry: Used in water supply and drainage systems to control the opening and closing of water flow.
Energy industry: In the cooling water system and steam system of power stations, it ensures the reliable transmission of media.
Food and pharmaceutical industries: Suitable for the control of clean fluids in the food and pharmaceutical industries.
A triple eccentric valve seals because the disc lands in a cone, not because rubber is squeezed. What each offset does, and why torque decides the leak.
In a soft seat butterfly valve the rubber liner is the seat, the flange gasket and the temperature limit. How it seals, how it fails, what to specify.
A bellows seal gate valve replaces the stuffing box with a welded metal bellows. Why the stem stops turning, what the tell-tale port shows, when packing wins.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.