| Availability: | |
|---|---|
| Quantity: | |
DIN DN100 PN16 CF8M Stainless Steel Flange Gate Valve with Manual Operation
Technical Parameters
Nominal Diameter: 1/2"~48" (DN15~DN1200)
Pressure Rating: 150LB~2500LB (PN20~PN420)
Applicable Temperature: -29°C~425°C
Applicable Media: water, steam, oil products, natural gas, acid gases, etc.
Materials:
Valve Body: CF8M stainless steel
Valve Bonnet: CF8M stainless steel
Valve Disc: CF8M stainless steel
Valve Stem: CF8M stainless steel
Sealing Surfaces: Stainless steel or hard alloy
Connection Method: Flanged connection, conforming to EN 1092-1 standard
Design Standards: DIN 320
Face-to-Face Dimension: DIN 3202
Testing Standards: EN 12266-1
Operation Method: Manual operation
Product Features
High-Strength Material: CF8M stainless steel has good mechanical properties and corrosion resistance, and is suitable for various working conditions.
Reliable Sealing: Adopting flanged connection and high-quality sealing surface design, it has excellent sealing performance and a long service life.
Manual Operation: Equipped with a manual operating mechanism, it can open and close quickly and operate flexibly.
Conformance to Standards: Its design and manufacture comply with the DIN 320 standard, and its testing complies with the DIN 3230 standard.
Multiple Options: Electric or pneumatic actuators can be equipped according to customer needs to achieve automated control.
Low Leakage Design: The valve stem adopts precision-machined ACME threads to reduce friction, prevent leakage and extend the service life of the valve stem.
Application Areas
Petroleum and Natural Gas Industry: Used in oil and gas transmission pipelines to control the flow of media such as oil and natural gas.
Chemical Industry: Suitable for the control of corrosive media in chemical production.
Water Treatment Industry: Used in water supply and drainage systems to control the opening and closing of water flow.
Energy Industry: In the cooling water systems and steam systems of power plants, it ensures the reliable transmission of media.
Food and Pharmaceutical Industry: Suitable for the control of clean fluids in the food and pharmaceutical industries.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.