| Availability: | |
|---|---|
| Quantity: | |
Structural Features
Carbon Steel Material: The valve body is made of high-quality carbon steel (WCB), which has high strength and good corrosion resistance. It can resist the erosion of various chemical media and extend the service life of the valve.
Flanged Connection: Adopts a standard flanged connection method that complies with the ASME B16.5 standard, ensuring the reliability and sealing performance of installation.
Pneumatic Actuator: Equipped with a high-performance pneumatic actuator, it enables fast and precise remote control and automatic operation. The actuator offers multiple options, such as double-acting and single-acting, to meet different control requirements.
Bidirectional Sealing: The unique sealing design ensures reliable sealing during both forward and reverse flow, effectively preventing medium leakage and ensuring the safe operation of the pipeline system.
Fire Safety Design: Compliant with the API 607 standard, the valve can maintain sealing performance even in case of fire, preventing medium leakage and ensuring system safety.
Anti-Static Device: Equipped with a built-in anti-static device, it effectively prevents static accumulation, reduces the risk of fire and explosion, and is particularly suitable for the control of flammable and explosive media.
Compact Design: With small size and light weight, it is easy to install and integrate into existing systems, saving space.
Multiple Operation Modes: It can be equipped with manual, pneumatic, electric, or hydraulic actuators to achieve remote automatic control.
Technical Parameters
Nominal Diameter: 4″ (DN100)
Pressure Class: 150LB (PN20)
Temperature Range: -29℃ to +425℃
Materials:
Valve Body: Carbon Steel (WCB)
Gate Disc: Carbon Steel (WCB) + Hard Alloy (e.g., Stellite No.6)
Valve Stem: Stainless Steel (304/316)
Sealing Material: PTFE, RPTFE
Connection Method: Flanged Connection (compliant with ASME B16.5 standard)
Operation Mode: Pneumatic
Design Standard: API 600, ASME B16.34
Testing Standard: API 598, ISO 5208
Fire Protection Design: API 607
Applicable Media: Water, Oil, Gas, Chemical Media, etc.
Application Scenarios
Oil and Natural Gas Industry: Used in oil and gas field exploration, gathering, transportation, and processing systems to ensure reliable isolation and control of media.
Chemical Industry: Suitable for the transportation and reaction systems of various chemical media, preventing medium leakage and ensuring production safety.
Pharmaceutical Industry: Applied in pipeline systems during pharmaceutical production to ensure medium isolation and cleanliness in the drug manufacturing process.
Food and Beverage Industry: Meets food-grade requirements and is used in pipeline systems for food and beverage production to ensure hygiene and safety.
HVAC: Used in cooling water systems, hot water systems, etc., to ensure efficient operation of the system.
General Industrial Applications: Suitable for the control and isolation of media such as water, oil, and gas.
Advantages and Value
High Reliability: The carbon steel material and compact design ensure the valve operates stably in medium-low pressure and medium-high temperature environments, reducing maintenance frequency and downtime.
High Safety: The fire protection, anti-static design, and reliable sealing performance effectively reduce the risk of leakage, safeguarding the safety of personnel and equipment.
Automatic Operation: The pneumatic actuator enables remote control and automatic operation, improving the flexibility and safety of the system.
Easy Installation and Maintenance: The flanged connection simplifies the installation process and facilitates maintenance and overhaul.
Wide Applicability: Multiple material options and a broad range of pressure and temperature allow it to adapt to various complex working conditions and medium characteristics.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.