| Availability: | |
|---|---|
| Quantity: | |
Pneumatic Actuated 3PC Stainless Steel Clamp Ball Valve
Product Features
Three-Piece Structure: The valve consists of three parts, facilitating quick disassembly and maintenance. There is no need to dismantle the entire pipeline system when replacing vulnerable parts like seals, which greatly reduces maintenance time and cost.
Pneumatic Actuator: Equipped with a high-precision pneumatic actuator, it supports remote control and automated operation, and can achieve quick on-off and precise adjustment.
Clamp Connection: Adopting the clamp connection method, it is convenient for installation and has good sealing performance, and is suitable for occasions with high hygienic requirements.
Material Advantage: The valve body and ball are made of high-quality stainless steel, which has good corrosion resistance and mechanical properties and is suitable for a variety of media.
Sealing Performance: High-performance sealing materials such as PTFE are adopted to ensure that the valve can achieve reliable sealing under various working conditions.
Multiple Control Modes: It supports single-acting (spring return) and double-acting pneumatic actuators to meet different process requirements.
Technical Parameters
Nominal Size: 1/2"~4" (DN15~DN100)
Working Pressure: 1000WOG
Working Temperature: -20 °C~180 °C
Valve Body Material: Stainless steel 304, 316, 316L, etc.
Sealing Material: PTFE
Connection Method: Clamp connection
Actuator Parameters:
Protection Grade: IP65/IP67
Output Torque: 10Nm to 4000Nm (options available for different models)
Running Time: 10 seconds to 58 seconds (depending on the model)
Control Mode: Single-acting (spring return), Double-acting
Application Scenarios
Food and Beverage Industry: Used to control fluid media in the production process of food and beverages, such as water, syrup, and fruit juice, to ensure the quality and safety of products.
Pharmaceutical Industry: In the drug production process, it is used to control the transportation and mixing of liquid medicine to meet hygienic requirements and ensure the quality and hygienic safety of the production process.
Chemical Industry: Used to control the transportation of corrosive chemical media such as acid, alkali, and salt solutions to ensure the safety and stability of the production process.
Water Treatment Industry: Used in water supply and drainage systems and sewage treatment plants to control the on-off and flow regulation of water to achieve the rational allocation and purification treatment of water resources.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.