| Availability: | |
|---|---|
| Quantity: | |
1/2“-10”
J-VALVES
Structural Features
Duplex Stainless Steel Material: The valve body is made of CN7M duplex stainless steel, which combines the advantages of austenitic and ferritic stainless steels. It features high strength, good corrosion resistance, and resistance to chloride stress corrosion, making it suitable for various media and working conditions.
Plug Design: Adopts a plug-type structure, ensuring simple operation and reliable sealing performance, which can effectively prevent medium leakage.
High Reliability: The design ensures stable operation under high-pressure and high-temperature environments, reducing maintenance frequency and downtime.
Fire Safety Design: Complies with relevant fire safety standards; even in case of fire, the valve can maintain sealing performance to safeguard the safety of personnel and equipment.
Anti-Static Device: A built-in anti-static device ensures electrical continuity, prevents static accumulation, and reduces the risk of fire and explosion.
Compact Design: With small size and light weight, it is easy to install and maintain, making it suitable for occasions with limited space.
Technical Parameters
Nominal Diameter: 4" (DN100)
Pressure Class: 150LB (PN2.0)
Temperature Range: -20℃ to +120℃
Materials:
Valve Body: CN7M Duplex Stainless Steel
Plug: CN7M Duplex Stainless Steel
Valve Stem: 316 Stainless Steel
Sealing Ring: Nitrile Butadiene Rubber (NBR) or Polytetrafluoroethylene (PTFE)
Connection Method: Flanged Connection (RF or RTJ), compliant with ANSI B16.5 standard
Operation Mode: Handwheel Operation
Design Standards: API 600, ASME B16.34
Testing Standards: API 598, ISO 5208
Application Fields
Oil and Natural Gas Industry: Used in oil and gas field exploration, gathering, transportation, and processing systems to control the flow direction of fluids and ensure the smooth progress of the production process.
Chemical Industry: Suitable for the transportation and reaction systems of various chemical media, preventing medium leakage and ensuring production safety.
Water Treatment Industry: Applied in the water supply and drainage systems of water plants and sewage treatment plants to control the on-off and flow direction of water, improving water treatment efficiency and water quality safety.
Food and Beverage Industry: Meets food-grade requirements and is used in pipeline systems during food and beverage production to ensure hygiene and safety.
HVAC: Used in cooling water systems, hot water systems, etc., to control the on-off and flow direction of water, ensuring the efficient operation of the system.
General Industrial Applications: Suitable for the control and isolation of media such as water, oil, and gas, ensuring the safe and efficient operation of the system.
Advantages and Value
High Reliability: The CN7M duplex stainless steel material and plug design ensure the valve operates stably under high-pressure and high-temperature environments, reducing maintenance frequency and downtime.
High Safety: The fire protection, anti-static design, and reliable sealing performance effectively reduce the risk of leakage, safeguarding the safety of personnel and equipment.
Easy Operation: The handwheel operation mode provides a stable and labor-saving operation experience, suitable for manual control.
Convenient Installation and Maintenance: The flanged connection simplifies the installation process and also facilitates maintenance and overhaul, reducing maintenance costs.
Wide Applicability: Multiple material options and a broad range of pressure and temperature make it adaptable to various complex working conditions and medium characteristics.
J-VALVES Service
● On Samples Buyer bear the air fee, but this fee will be reduced from order directly
● On After Sales Free replacement if there is any quality problem
● On Delivery Never delay delivery time
● On Materials Ensure material pure
● Ensure material pure
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.