| Availability: | |
|---|---|
| Quantity: | |
API 150LB Carbon Steel WCB LUG Wafer Check Valve
Design Features
Material:
Valve Body: Carbon steel WCB, which is suitable for medium and high-pressure environments.
Valve Disc: Carbon steel WCB, ensuring a long service life in harsh environments.
Connection Method: Butterfly connection, which complies with the ASME B16.47B standard, ensuring a reliable connection between the valve and the piping system.
Operation Mode: Automatic operation, without the need for external power. It automatically opens and closes relying on fluid pressure.
Double Disc Design: The valve discs automatically open under the action of fluid pressure and automatically close after the fluid passes through to prevent the backflow of media.
Spring-assisted Closing: Equipped with a spring-assisted closing mechanism to ensure quick and reliable sealing and reduce the water hammer phenomenon.
Fireproof Design: It complies with the API 607 fire safety standard, ensuring the sealing performance of the valve under fire conditions.
Sealing Materials: The valve seat uses PTFE or other high-performance sealing materials, which are suitable for a variety of media and temperature ranges.
Technical Parameters
Nominal Diameter: 2" ~ 84" (DN50 ~ DN2100)
Pressure Rating: 150LB ~ 2500LB (PN20 ~ PN420)
Applicable Media: Water, oil, natural gas, steam, etc.
Applicable Temperature: -29℃ ~ 200℃
Valve Body Material: Carbon steel WCB
Valve Disc Material: Carbon steel WCB
Sealing Materials: PTFE, PEEK, etc.
Connection Method: Butterfly connection
Design Standard: API 594
Testing Standard: API 598
Face-to-Face Dimensions: ASME B16.10
Application Fields
Petroleum and Natural Gas Industry: Used in the transportation, storage, and processing systems of petroleum and natural gas.
Chemical Industry: Used to control the flow of corrosive media.
Water Treatment Industry: Used in the water transportation and treatment systems.
Energy Industry: Used in the cooling water systems and steam systems of power plants.
Offshore Engineering: Used for fluid control in seawater systems and offshore platforms.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.