| Availability: | |
|---|---|
| Quantity: | |
J-VALVES-BV
J-VALVES
8481804090
2PC Flange End Stainless Steel CF8m Reduce Bore Floating Ball Valve
Technical Parameters
Nominal Diameter: 1/4"~12" (DN6~DN300)
Pressure Rating: 150LB~2500LB (PN20~PN420)
Temperature Range: -29℃ to 200℃
Applicable Media: water, natural gas, oil, corrosive liquids, etc.
Valve Body Material: CF8, CF8m, CF3, CF3m stainless steel
Ball Material: 304, 316 stainless steel
Seat Material: PTFE, RPTFE
Connection Method: Flanged connection
Operation Mode: Manual, Electric, Pneumatic
Design Standards: API 608, API 6D, ASME B16.34
Testing Standard: API 598
Fire Safety: Complies with API 607 fire safety standard
Anti-static Design: Equipped with anti-static device
Design Features
Floating Ball Design: The ball can float freely under the action of the medium pressure, automatically adjust the sealing position to ensure the sealing performance.
Reduce Bore Design: The Reduce Bore design reduces the resistance when fluid passes through and improves system efficiency.
Flanged Connection: The flanged connection method is adopted, which is convenient for installation and has reliable sealing.
Fire Safety: Complies with API 607 fire safety standard and can maintain the sealing performance in case of fire.
Anti-static Device: Prevents the accumulation of static electricity and is suitable for flammable and explosive media.
ISO 5211 Mounting Interface: With a standard ISO 5211 mounting interface, it is convenient to install actuators.
Application Scenarios
Petroleum and Natural Gas Industry: Used in oil and gas transmission pipelines, wellhead control, refineries and natural gas processing plants, etc.
Chemical Industry: Applicable to pipeline systems for handling corrosive chemicals, such as the transportation of acids, alkalis and solvents.
Power Industry: Used in the cooling water systems and steam systems of power plants.
Municipal Water Supply and Sewage Treatment: To ensure the safety of water quality and the stable operation of the systems.
Food and Pharmaceutical Industry: Applicable to hygienic pipeline systems to ensure the purity and non-pollution of the media.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.