| Availability: | |
|---|---|
| Quantity: | |
Compliance with International Standards: The design, manufacturing and testing comply with international standards such as DIN 3352 and EN 1984.
High-Strength Material: The valve body is made of carbon steel GS-C25, which has excellent high-temperature strength and creep resistance, suitable for high-temperature and high-pressure environments.
Excellent Sealing Performance: Equipped with a flexible wedge gate and a stainless steel sealing surface, it has outstanding sealing performance and can achieve bidirectional sealing to ensure no medium leakage.
Reliable Flange Connection: Adopts flange connection conforming to DIN standards, featuring reliable connection and convenient installation and maintenance.
Flexible Operation: Equipped with a handwheel operating mechanism, it is flexible to open and close and easy to operate. Optional gear operating mechanism or electric actuator is available, suitable for large-diameter valves or remote control.
Low-Emission Design: Equipped with low-emission packing, which meets environmental protection requirements and reduces the risk of medium leakage.
Wide Application Range: Suitable for various media such as water, steam, oil products, natural gas and corrosive media.
Nominal Diameter: DN150
Pressure Rating: PN16
Applicable Media: Water, steam, oil products, natural gas, corrosive media, etc.
Operating Temperature: -29℃ to 400℃ (the specific temperature range depends on the seals and media)
Valve Body Material: Carbon steel GS-C25
Stem Material: Stainless steel (such as 1.4021)
Sealing Surface Material: Stainless steel 1.4021 or cemented carbide
Connection Method: Flange connection (RF)
Operation Mode: Handwheel operation, optional gear operation or electric actuator
Design Standards: DIN 3352, EN 1984
Testing Standard: EN 12266-1
Structure length: Conforming to EN 558-1 standard
Oil and Gas Industry: Used in oil and gas transmission pipelines to control the on-off of fluids and ensure the safe operation of pipeline systems.
Chemical Industry: Suitable for the transportation and control of chemical media, preventing medium leakage and protecting equipment and personnel safety.
Power Industry: Used in cooling water systems and steam systems of power stations to ensure reliable control of fluids.
Water Treatment Industry: Used in water supply systems and sewage treatment systems to control the on-off of water flow.
A bellows seal gate valve replaces the stuffing box with a welded metal bellows. Why the stem stops turning, what the tell-tale port shows, when packing wins.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.