| Availability: | |
|---|---|
| Quantity: | |
Electric Actuator 3PC Stainless Steel Thread Ends Floating Ball Valve
Product Features
Structural Design: It features a three-piece structure, which is convenient for disassembly and maintenance. It allows for quick replacement of vulnerable parts like seals, reducing downtime.
Sealing Performance: High-performance sealing materials such as PTFE are adopted, and the floating ball design ensures good sealing performance, achieving zero leakage.
Material Advantage: The valve body is made of stainless steel, which has strong corrosion resistance and is suitable for a variety of media.
Easy Operation: Equipped with an electric actuator, it supports remote signal control or local operation, and can realize multiple functions such as on-off control and regulating control.
Wide Application Range: It is applicable to various media such as water, oil, gas, acid, and alkali, and is widely used in industries such as chemical, petroleum, natural gas, water treatment, and food.
Technical Parameters
Nominal Size: 1/4"~4" (DN6~DN100)
Working Pressure: 1000WOG
Medium Temperature: -10 °C~180 °C
Ambient Temperature: -20 °C~70 °C
Valve Body Material: Stainless steel 304/316/316L, etc.
Sealing Material: PTFE, etc.
Connection Method: Threaded connection
Actuator Parameters:
Power Supply Voltage: 24V AC/DC, 110V AC, 220V AC, 380V AC, etc.
Protection Grade: IP65/IP67
Output Torque: 10Nm - 4000Nm (options available for different models)
Running Time: Varying from 10s to 58s (depending on the model)
Control Mode: On-off type, regulating type, intelligent type, etc.
Application Scenarios
Chemical Industry: It is used to control the transportation of corrosive chemical media, such as acid, alkali, and salt solutions.
Petroleum and Natural Gas Industry: In the processes of oil and gas exploration, transportation, and processing, it is used to control the flow of oil and gas.
Water Treatment Industry: It is used in water supply and drainage systems, sewage treatment plants, etc., to control the on-off and flow regulation of water.
Food and Beverage Industry: It is used to control fluid media in the production process of food and beverages, such as water, syrup, and fruit juice.
Pharmaceutical Industry: It is used in the drug production process to control the transportation and mixing of liquid medicine.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.
ISO 5208 Rates A-G explained with real numbers, how API 598, API 6D and FCI 70-2 map across, and what metal seats can honestly achieve.
How to choose a forged or cast valve body: API 600 vs API 602 size limits, casting quality factor, NDT coverage, weld repair policy and cost crossovers.
How pressure seal bonnet valves work, why bolted bonnets stop at Class 900, seal ring materials, disassembly rules and the low-pressure leak signature.