| Availability: | |
|---|---|
| Quantity: | |
Double-Disc Design: Equipped with two independent discs, which can close quickly when the fluid flows backward, providing double sealing protection and effectively preventing fluid backflow.
Stainless Steel CF8 Material: The valve body and main components are made of stainless steel CF8, which has good corrosion resistance and high-temperature resistance, suitable for various media.
High Pressure Rating: With a pressure rating of 300LB, it can withstand high working pressure and is suitable for high-pressure pipeline systems.
Compact Structure: The wafer structure design features small volume, light weight, convenient installation, and space saving.
Automatic Operation: No external power or manual operation is required; it completely relies on fluid pressure to automatically control the opening and closing of the discs.
Reliable Sealing Performance: The disc and valve seat are precision-machined, resulting in excellent sealing performance, which can remain good even after long-term use.
Simple Maintenance: The structure is simple, easy to disassemble and maintain, reducing maintenance costs and time.
Nominal Diameter: 2"~84" (DN50~DN2100)
Pressure Rating: 150LB~2500LB
Applicable Media: Water, steam, oil products, natural gas, corrosive media, etc.
Working Temperature: -20℃ to 350℃ (the temperature range may vary depending on the material and seals)
Connection Method: Flanged connection (RF)
Design Standards: API 594, ASME B16.34
Testing Standard: API 598
Materials:
Valve body: Stainless steel CF8
Disc: Stainless steel CF8
Sealing surface: Stainless steel or cemented carbide
Operation Mode: Automatic
Oil and Gas Industry: Used in natural gas transmission pipelines to prevent gas backflow and protect the safety of the pipeline system.
Chemical Industry: Used in pipeline systems for transporting corrosive media to prevent medium backflow and avoid equipment corrosion.
Power Industry: Used in cooling water systems and steam systems of power stations to ensure one-way fluid flow.
Water Treatment Industry: Used in water supply systems to prevent water backflow and protect water pumps and pipelines.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.