Bronze C95800 Wafer Type Double Flanged Double Disc Check Valve
Aluminum Bronze Material: The valve body and key components are made of ASTM B148 C95800 aluminum bronze, with excellent corrosion resistance and high strength.
Double Flanged Connection: Adopts a double flanged connection method, conforming to ASME B16.5 standards, ensuring reliable installation and sealing performance.
Double Disc Design: The double disc design ensures one-way flow of the medium, effectively preventing backflow and reducing wear.
Fire Safety Design: Complies with API 607 standards, ensuring the valve maintains sealing performance even in case of fire to prevent medium leakage.
Anti-Static Device: Built-in anti-static device effectively prevents static accumulation, reducing the risk of fire and explosion.
Compact Design: Small in size and light in weight, facilitating installation and integration into existing systems.
Size Range: 2″ to 48″ (DN50 to DN1200)
Pressure Class: 150LB to 2500LB (PN20 to PN420)
Temperature Range: -29℃ to +300℃
Materials:
Valve Body: ASTM B148 C95800
Disc: ASTM B148 C95800
Sealing Material: PTFE, NBR, EPDM, FPM
Connection Method: Double flanged connection
Design Standards: API 594, ASME B16.34
Testing Standards: API 598
Face-to-Face Dimensions: Compliant with ASME B16.10 standards
Seawater Treatment: Suitable for seawater-related applications such as seawater desalination, offshore platforms, and ships.
Oil and Gas Industry: Used in exploration, gathering, and processing systems of oil and gas fields to ensure reliable isolation and control of media.
Chemical Industry: Applicable to transportation and reaction systems of various chemical media, preventing medium leakage and ensuring production safety.
Pharmaceutical Industry: Used in pipeline systems during pharmaceutical production to ensure medium isolation and cleanliness in the drug manufacturing process.
Food and Beverage Industry: Meets food-grade requirements, used in pipeline systems for food and beverage production to ensure hygiene and safety.
HVAC: Used in cooling water systems, hot water systems, etc., to ensure efficient operation of the system.
High Reliability: The aluminum bronze material and double disc design ensure stable operation of the valve in high-pressure and high-temperature environments, reducing maintenance frequency and downtime.
High Safety: Fire-resistant and anti-static designs, along with reliable sealing performance, effectively reduce leakage risks and ensure the safety of personnel and equipment.
Easy Installation and Maintenance: The double flanged connection simplifies the installation process and facilitates maintenance and overhaul.
Wide Application Range: Multiple material options and a broad range of pressure and temperature make it adaptable to various complex working conditions and medium characteristics.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.