| Availability: | |
|---|---|
| Quantity: | |
Dual Isolation Function: The valve is internally designed with two independent sealing balls, enabling dual isolation to ensure no medium leakage during maintenance or overhaul.
Bleed Function: Equipped with one bleed port, which can safely discharge residual media in the pipeline after isolation, preventing media accumulation and pressure buildup.
Floating Ball Design: The ball can float freely under the pressure of the medium, fitting tightly with the valve seat to form an excellent sealing effect, and also has an automatic pressure relief function.
Fire Safety Design: Complies with API 607 standards. Even in case of fire, the valve can still maintain sealing performance to prevent safety accidents caused by medium leakage.
Anti-Static Device: Built-in anti-static device effectively prevents static accumulation, reducing the risk of fire and explosion.
Flange Connection: Multiple flange connection methods are available, conforming to ASME B16.5 standards, ensuring installation reliability and compatibility.
Compact Design: 3-piece structure reduces installation space and weight, while lowering installation costs.
Size Range: 1/2″ to 8″(DN15 to DN200)
Pressure Range: ASME Class 150 to Class 1500 (PN20 to PN260)
Temperature Range: -50℃ to 240℃
Material Options:
Valve body: A105, F304 (L), F316 (L), LF2, F11, F51, etc.
Ball: A105+ENP, F304 (L), F316 (L), F51, etc.
Valve seat: PTFE, PEEK, NYLON, etc.
Connection Methods: Flange connection (RF), threaded connection (NPT), butt-welded connection (BW), socket-welded connection (SW)
Operation Modes: Various actuators available, including manual, electric, and pneumatic
Design Standards: API 6D, API 608, ASME B16.34
Testing Standards: API 598
Oil and Gas Industry: Used in exploration, gathering, processing, and transportation systems of oil and gas fields to realize isolation, control, and discharge of oil and gas.
Chemical Industry: Suitable for transportation and reaction systems of various chemical media, preventing medium leakage and ensuring production safety.
Pharmaceutical Industry: Applied in pipeline systems during pharmaceutical production to ensure medium isolation and cleanliness in the drug manufacturing process.
Food and Beverage Industry: Meets food-grade requirements, used in pipeline systems for food and beverage production to ensure hygiene and safety.
Urban Gas Industry: Used in pressure regulating stations, gas storage stations, and gas transmission pipelines of urban gas networks to ensure safe supply and stable transportation of gas.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.