Product Features
High-quality Materials: The valve body is made of 304 stainless steel, which has high strength and excellent corrosion resistance, and can adapt to extremely Cryogenic environments.
Extended Stem Design: The unique extended stem design makes it easy to install and operate in deep wells or other hard-to-reach places.
Flange Connection: The flange connection method is adopted, which complies with ANSI and DIN standards, ensuring a quick and reliable connection between the valve and the pipeline system, and facilitating installation and maintenance.
Reliable Sealing: High-quality sealing materials such as PTFE and graphite are used to ensure that the valve can still maintain good sealing performance at low temperatures.
Convenient Operation: Equipped with a handwheel operation mechanism, it is flexible and convenient to operate, enabling precise control.
Fire-safe Design: Complies with API 607 fire-safe standards, suitable for high-risk environments.
Anti-static Design: Equipped with an anti-static device to ensure safety in flammable and explosive environments.
Multiple Standards Compliance: Complies with international standards such as API 602 and ASME B16.34, ensuring the reliability of product quality and performance.
Technical Parameters
Nominal Pressure: 300LB
Size Range: 2 inch (DN50)
Operating Temperature: -196°C to 200°C
Applicable Media: Liquefied natural gas (LNG), liquid nitrogen, liquid oxygen, air, etc.
Valve Body Material: 304 stainless steel
Valve Disc Material: 304 stainless steel
Valve Stem Material: 304 stainless steel
Sealing Material: PTFE, graphite
Connection Method: Flange connection
Operation Method: Manual
Design Standards: API 602, ASME B16.34
Inspection and Testing: API 598
Sealing Class: ANSI B16.104 Class VI
Application Areas
This valve is widely used in the following fields:
Liquefied Natural Gas (LNG): LNG receiving terminals, LNG carriers, LNG refueling stations, etc.
Chemical Industry: Storage and transportation of Cryogenic media such as liquid nitrogen and liquid oxygen.
Pharmaceutical Industry: Control and transportation of Cryogenic media.
Food Industry: Control of liquid nitrogen refrigeration systems.
Research Institutions: Fluid control of Cryogenic experimental equipment.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.