| Availability: | |
|---|---|
| Quantity: | |
1/2“-10”
J-VALVES
Structural Features
Forged Stainless Steel Material: The valve body is made of high-quality forged stainless steel (e.g., 304, 316, 316L), which has high strength and good corrosion resistance. It can resist the erosion of various chemical media and extend the valve’s service life.
Floating Ball Design: The ball can float freely under the pressure of the medium and fits tightly with the valve seat to form an excellent sealing effect, ensuring no leakage risk.
All-Welded Structure: The valve body adopts an all-welded process, which eliminates the risk of external leakage and improves the overall strength and sealing performance of the valve.
Cryogenic Design: The valve undergoes deep cryogenic treatment, allowing it to adapt to extremely low-temperature environments and ensuring reliable operation under low-temperature conditions.
Fire-Safe Design: Complies with the API 607 standard. Even in case of fire, the valve can maintain sealing performance to prevent medium leakage and ensure system safety.
Anti-Static Device: Equipped with a built-in anti-static device, which effectively prevents static accumulation, reduces the risk of fire and explosion, and is particularly suitable for controlling flammable and explosive media.
Compact Design: Small in size and light in weight, it is easy to install and integrate into existing systems, saving space.
Multiple Operation Modes: Can be equipped with manual, pneumatic, electric, or hydraulic actuators to achieve remote and automated control.
Technical Parameters
Nominal Diameter: 1/2″ to 10″ (DN15 to DN250)
Pressure Rating: 150LB to 2500LB (PN10 to PN420)
Temperature Range: -196℃ to +200℃
Materials:
Valve Body: Forged Stainless Steel (304, 316, 316L)
Ball: Forged Stainless Steel (304, 316, 316L)
Valve Stem: Forged Stainless Steel (304, 316, 316L)
Sealing Material: PTFE, RPTFE
Connection Type: Flange connection (compliant with ASME B16.5 standard), Butt Weld (BW) connection
Operation Mode: Manual, pneumatic, electric, hydraulic
Design Standards: API 6D, ASME B16.34
Testing Standards: API 598, ISO 5208
Fire-Safe Design: API 607
Applicable Media: Cryogenic media such as liquefied natural gas (LNG), liquefied petroleum gas (LPG), liquid oxygen, liquid nitrogen, etc.
Application Scenarios
Oil and Natural Gas Industry: Used in storage and transportation systems of liquefied natural gas (LNG) and liquefied petroleum gas (LPG) to ensure reliable isolation and control of media.
Chemical Industry: Suitable for conveying and reaction systems of various cryogenic chemical media, preventing medium leakage and ensuring production safety.
Pharmaceutical Industry: Applied in cryogenic pipeline systems during pharmaceutical production to ensure medium isolation and cleanliness in the drug manufacturing process.
Food and Beverage Industry: Meets food-grade requirements, used in cryogenic pipeline systems for food and beverage production to ensure hygiene and safety.
HVAC: Used in cooling water systems, hot water systems, etc., to ensure efficient operation of the system.
General Industrial Applications: Suitable for controlling and isolating media such as water, oil, and gas.
Advantages and Value
High Reliability: The forged stainless steel material and floating ball design ensure the valve operates stably in extremely low-temperature environments, reducing maintenance frequency and downtime.
High Safety: Fire-resistant and anti-static designs, along with reliable sealing performance, effectively reduce leakage risks and protect the safety of personnel and equipment.
Automated Operation: Multiple actuator options enable remote control and automated operation, improving system flexibility and safety.
Easy Installation and Maintenance: The flange connection simplifies the installation process and facilitates maintenance and overhaul.
Wide Applicability: Multiple material options and a broad range of pressure and temperature ratings allow the valve to adapt to various complex working conditions and medium characteristics.
Note: All the data should be confirmed with the approved drawings of manufacturer.
Tips:
We also manufacture other type valves, as butterfly valve, check valve, globe valve, Y strainer, sanitary butterfly valve, sanitary ball and so on.
Any item meets your interest, anything confused you, pls keep me posted, let's talk more.
J-VALVES Service:
On Samples Buyer bear the air fee, but this fee will be reduced from order directly
On After Sales Free replacement if there is any quality problem
On Delivery Never delay delivery time
On Materials Ensure material pure
Ensure material pure
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.