| Availability: | |
|---|---|
| Quantity: | |
Structural Features
Stainless Steel Material: The valve body, ball, and valve stem are all made of high-quality stainless steel (e.g., 316), which has high strength and good corrosion resistance. It can resist the erosion of various chemical media and extend the service life of the valve.
3-Way Design: Two channel designs are available: L-type and T-type. The L-type is used for flow diversion, while the T-type is used for fluid mixing or distribution, meeting different fluid control requirements.
Pneumatic Actuator: Equipped with a high-performance pneumatic actuator, it enables fast and precise remote control and automatic operation. The actuator offers two types: single-acting and double-acting, which can be selected according to specific needs.
Fire Safety Design: Compliant with the API 607 standard, the valve can maintain sealing performance even in case of fire, preventing medium leakage and ensuring system safety.
Anti-Static Device: Built-in anti-static device effectively prevents static accumulation, reduces the risk of fire and explosion, and is particularly suitable for the control of flammable and explosive media.
Compact Design: With small size and light weight, it is easy to install and integrate into existing systems, saving space.
Multiple Connection Methods: Flanged connection is available, complying with ASME B16.5 or DIN standards, ensuring the reliability and sealing performance of installation.
Technical Parameters
Nominal Diameter: 1/2″ to 12″ (DN15 to DN300)
Pressure Class: 150LB to 600LB (PN20~PN100)
Temperature Range: -29℃ to +425℃
Materials:
Valve Body: Stainless Steel (316)
Ball: Stainless Steel (316)
Valve Stem: Stainless Steel (316)
Sealing Material: PTFE, RPTFE
Connection Method: Flanged Connection (complying with ASME B16.5 or DIN standards)
Operation Mode: Pneumatic (Single-acting, Double-acting)
Design Standard: ASME B16.34, API 6D
Testing Standard: API 598
Fire Protection Design: API 607
Applicable Media: Water, Oil, Gas, Chemical Media, etc.
Application Scenarios
Oil and Natural Gas Industry: Used in oil and gas field exploration, gathering, transportation, and processing systems to ensure reliable isolation and control of media.
Chemical Industry: Suitable for the transportation and reaction systems of various chemical media, preventing medium leakage and ensuring production safety.
Pharmaceutical Industry: Applied in pipeline systems during pharmaceutical production to ensure medium isolation and cleanliness in the drug manufacturing process.
Food and Beverage Industry: Meets food-grade requirements and is used in pipeline systems for food and beverage production to ensure hygiene and safety.
HVAC: Used in cooling water systems, hot water systems, etc., to ensure efficient operation of the system.
General Industrial Applications: Suitable for the control and isolation of media such as water, oil, and gas.
Advantages and Value
High Reliability: The stainless steel material and compact design ensure the valve operates stably in medium-high pressure and medium-high temperature environments, reducing maintenance frequency and downtime.
High Safety: The fire protection, anti-static design, and reliable sealing performance effectively reduce the risk of leakage, safeguarding the safety of personnel and equipment.
Automatic Operation: The pneumatic actuator enables remote control and automatic operation, improving the flexibility and safety of the system.
Easy Installation and Maintenance: The flanged connection simplifies the installation process and facilitates maintenance and overhaul.
Wide Applicability: Multiple material options and a broad range of pressure and temperature allow it to adapt to various complex working conditions and medium characteristics.
How pressure seal bonnet valves work, why bolted bonnets stop at Class 900, seal ring materials, disassembly rules and the low-pressure leak signature.
A lift check valve closes in millimetres, not degrees. Disc lift, cracking pressure, chatter, and why steam and compressor duty punish a badly sized one.
Category A and Category B butterfly valves differ at the seat, not the body. What each one seals with, where each leaks, and what to put on the datasheet.
Butterfly vs gate valve compared by loss coefficient, pumping energy cost, weight, torque and leakage class, with selection rules and datasheet data.
How solid, flexible and split wedges differ in sealing, thermal binding and misalignment tolerance, plus selection rules and RFQ data.
The backseat, the gland and the blowout-proof stem decide whether a gate valve leaks at the stem, and whether it can be repacked with the line still live.
A fire-safe valve must still isolate after its soft seat has burned away. What API 607 and ISO 10497 test, and what the certificate does not cover.
How to size pneumatic valve actuators: valve torque, safety factors, spring-return vs double-acting, air pressure, stroking time and fail-safe position.
What the sleeve actually seals againstA sleeve type plug valve has three parts in the sealing path: a metal plug with a through port, a moulded sleeve of PTFE or PFA that wraps the plug and carries its own matching port, and a metal body liner behind the sleeve. Nothing is injected and nothing is gr
Bronze, 90/10 cupronickel, duplex, super duplex and Monel in seawater: what pits, what erodes, and how to write the material call-out.
Why check valves slam, what the Joukowsky surge really depends on, and how to select swing, dual plate and spring-loaded checks by flow deceleration.
Y-type, basket and duplex strainers sized by open area ratio: mesh openings in micron, clean and dirty pressure drop, and why baskets fail on steam.
Wafer, lug and double flanged butterfly valves compared: bolting, dead-end service, removal, gasket faces and where each body style fails.
Triple offset butterfly valves seal metal to metal with zero rubbing travel. Compare offsets, torque curves and seat materials for high temperature duty.
Learn about 5A gate valve material properties, pressure-retaining design, corrosion resistance and industrial applications. Explore J-VALVES solutions for demanding valve service requirements.
API 609 stops at NPS 60, AWWA C504 at 72 in. What really governs a DN2000 butterfly valve: offsets, shaft deflection, velocity and six failure chains.
Bellows seal globe valves fail at year two, not year ten. Three limits: cycle budget, fouled convolutions, load path. ISO 15848-1 classes included.
Discover how centerline wafer butterfly valves work, including disc design, seat sealing, flange installation and industrial applications. Explore J-VALVES valve solutions for water and general process systems.
Explore DBB reduced-bore ball valve design, sealing logic, oil and gas applications, and checks for materials, end connections, ratings, and test records.
Explore welded cryogenic butterfly valve design, material selection, sealing considerations and LNG applications. Learn how J-VALVES supports industrial valve solutions for low-temperature service.