Main Features
Diversified material selection: It offers a variety of materials such as cast iron, ductile iron, carbon steel, stainless steel, duplex stainless steel, super duplex stainless steel, nickel alloy, nickel-aluminum bronze, Hastelloy, Inconel, etc., to meet the requirements for corrosion resistance and strength under different working conditions.
Extensive size range: The sizes range from 2 inches to 34 inches, enabling it to adapt to pipeline systems from small to large ones.
Wide range of applicable media: It is suitable for various media such as water, natural gas, oil, and some corrosive liquids, meeting the needs of different industrial scenarios.
Multiple operation modes: It can be equipped with handle or gear operating devices, allowing users to choose manual or mechanical operation modes according to actual needs.
Strict design and manufacturing standards: It is designed and manufactured in accordance with international standards such as API 6D, API 608, and API 607 to ensure the reliability of product quality and performance.
Reliable sealing performance: Through advanced sealing technology, it can maintain a good sealing effect within the specified temperature and pressure ranges, reducing the risk of leakage.
Compact structural design: The wafer-style structure makes it compact in size, facilitating installation in pipeline systems with limited space and also reducing installation costs.
Product Features
Size: 2"~60" (DN50~DN1500)
Pressure Rating: 150LB~900LB (PN20~PN150)
Suitable Temperature: -27℃~150℃
Material: A351CF8M/CF8/CF3/CF3M/A216 WCB/A217 WC6/WC9/A105/GG25/GGG50/Titanium/BronzeC95800/C5/C12/Cryogenic steel
Test standard: API 6D, API 608, API 607, GB/T 12238, GB/T 12224, GB/T 12221, GB/T 9113, GB/T 13927, etc.
Structure Type: Center line pattern,Double Eccentric pattern,Three Eccentric pattern
Reliable sealing performance: Through advanced sealing technology, good sealing effects can be maintained under various pressure and temperature conditions, effectively preventing media leakage and ensuring the safe operation of the system.
Compact design: The wafer type connection method makes the valve easy to install and occupies a small space, making it suitable for use in pipeline systems with limited space.
Application Fields
J-VALVES Wafer Type Butterfly Valves are widely used in industries such as petroleum, natural gas, chemical engineering, water treatment, heating, ventilation and air conditioning, etc. They are used to control and regulate the fluid flow in pipelines, helping to achieve efficient operation and safe control of the system.
Competitive Advantage:
On Samples Buyer bear the air fee, but this fee will be reduced from order directly
On After Sales Free replacement if there is any quality problem
On Delivery Never delay delivery time
On Materials Ensure material pure
Ensure material pure
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.