| Availability: | |
|---|---|
| Quantity: | |
J-VALVES-BV
J-VALVES
8481804090
6× 4" 2500LB F316/F304/Lf2 RB Flanged Trunnion Mounted Ball Valve
Technical Parameters
Nominal Diameter: 1/2"~56" (DN15~DN1400)
Pressure Rating: 150LB~2500LB (PN20~PN420)
Temperature Range:
For metal seat: -196℃ ~ 425℃
For soft seat: -196℃ ~ 200℃
Applicable Media: water, natural gas, oil, corrosive liquids, etc.
Valve Body Material: F316 or F304 stainless steel
Ball Material: F316 or F304 stainless steel
Seat Material: PTFE, RPTFE, metal seat
Connection Method: Flanged connection
Operation Mode: Manual, Electric, Pneumatic
Design Standards: API 6D, API 608, ASME B16.34
Testing Standard: API 598
Fire Safety: Complies with API 607 fire safety standard
Anti-static Design: Equipped with anti-static device
Design Features
Trunnion Mounted Ball Design: The ball is fixed by the upper and lower shafts, reducing the operating torque and improving the stability and reliability of the valve.
Three-piece Flange Structure: It is convenient for quick disassembly and maintenance, and the internal components can be replaced without removing the entire valve from the pipeline.
Fire Safety: Complies with API 607 fire safety standard and can maintain the sealing performance in case of fire.
Anti-static Device: Prevents the accumulation of static electricity and is suitable for flammable and explosive media.
ISO 5211 Mounting Interface: With a standard ISO 5211 mounting interface, it is convenient to install actuators.
Bi-directional Sealing: The floating seat design realizes bi-directional sealing, ensuring reliable closure under any flow direction.
Advantages
High Sealing Performance: The PTFE or metal seats provide reliable sealing performance, ensuring zero leakage.
Strong Corrosion Resistance: The F316/F304 stainless steel materials exhibit excellent corrosion resistance in a variety of corrosive media.
Convenient Maintenance: The three-piece flange design facilitates quick disassembly and replacement of internal components, reducing maintenance costs.
Fire Safety: Complies with API 607 fire safety standard and is applicable to high-risk environments.
Wide Applicability: Applicable to a variety of media and working conditions, including high-temperature, high-pressure and corrosive environments.
Application Scenarios
Petroleum and Natural Gas Industry: Used in oil and gas transmission pipelines, wellhead control, refineries and natural gas processing plants, etc.
Chemical Industry: Applicable to pipeline systems for handling corrosive chemicals, such as the transportation of acids, alkalis and solvents.
Power Industry: Used in the cooling water systems and steam systems of power plants.
Municipal Water Supply and Sewage Treatment: To ensure the safety of water quality and the stable operation of the systems.
Food and Pharmaceutical Industry: Applicable to hygienic pipeline systems to ensure the purity and non-pollution of the media.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.