| Availability: | |
|---|---|
| Quantity: | |
J-VALVES-CV-1620
J-VALVES
8481804090
Product Features
High-quality Material: The valve body is made of F304 stainless steel, which has good corrosion resistance and high-temperature resistance, and is suitable for various media.
Efficient Sealing: Adopts a lift-type disc design, and the disc closely fits the valve seat to ensure unidirectional fluid flow and prevent medium backflow.
Automatic Operation: Automatically controls the opening and closing of the disc based on the fluid pressure difference without manual intervention, ensuring unidirectional fluid flow.
Compact Structure: Compact design and light weight make it easy to install and maintain.
Standard Compatibility: The flange connection end complies with ANSI B16.5 standards to ensure compatibility with existing pipeline systems.
Technical Specifications
Nominal Pressure: 300LB
Applicable Temperature: -196℃ to 573℃
Valve Body Material: F304 stainless steel
Connection Mode: Flange connection (RF)
Applicable Media: Water, steam, natural gas, oil, corrosive liquids, etc.
Design Standards: API 602, ASME B16.34, etc.
Testing Standard: API 598
Application Fields
Petrochemical industry: Prevents the backflow of corrosive media and protects equipment from corrosion.
Municipal water supply: Prevents water backflow and protects water pumps and pipeline systems.
HVAC: Ensures the unidirectional flow of hot and cold water and maintains the stable operation of the system.
Power industry: Used for unidirectional control of steam and water systems to ensure system safety.
Ocean engineering: Suitable for corrosive environments such as seawater to ensure the reliability of fluid control.
Advantages and Services
Customized Services: Customized design can be provided according to the specific needs of customers to meet the requirements of special working conditions.
Quality Assurance: All valves have passed 100% factory inspection.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.
Test water, end caps, desiccant and stem position: what six months in a yard does to a stored valve, and the incoming checks that catch it first.
Shrinkage, gas porosity, sand and hot tears in cast steel valve bodies: what radiography, ultrasonic, magnetic particle and penetrant testing each can find.
Flash vessel design and flash steam recovery: flash fraction formula, Souders-Brown sizing, hold-up, LP header and deaerator routing, failure diagnosis.
Wet shaft and dry shaft butterfly valves: what reaches the bearing, which part wears first, and why the disc stops centering in the bore.
Steam trap selection: float, inverted bucket, thermodynamic and thermostatic types, sized on load times safety factor at true differential pressure.
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.