| Availability: | |
|---|---|
| Quantity: | |
DIN Cast Steel Flanged Y Strainer
Main Features
Sturdy and Durable: Made of cast steel, it has high strength and good pressure resistance, can adapt to various complex working conditions and withstand relatively high working pressures.
High-efficiency Filtration: Equipped with a built-in stainless steel filter screen, it has high filtration precision and can effectively intercept impurity particles in the fluid to ensure the cleanliness of the fluid. The pore size of the filter screen can be selected according to different requirements to meet specific filtration needs.
Convenient Maintenance: The flange connection method facilitates installation and disassembly. Users can easily open the filter to clean or replace the filter screen without the need for complicated tools or equipment, which greatly reduces maintenance costs and time.
Strong Adaptability: It is suitable for a variety of media, such as water, oil, steam, gas, etc., and can be widely used in multiple industries such as chemical engineering, petroleum, pharmaceuticals, food processing, and energy.
Reliable Sealing: Equipped with high-quality seals to ensure no leakage under working pressure and guarantee the safe operation of the system.
Technical Parameters
Nominal Diameter: 1/2"~24" (DN15~DN600)
Working Pressure: 150LB~1500LB (PN20~PN260)
Working Temperature: -29℃~425℃
Filter Screen Material: Usually made of stainless steel materials such as SS304 and SS316, which have good corrosion resistance and filtration performance.
Connection Method: Flange connection, which complies with the DIN standard to ensure good connection and sealing with the pipeline system.
Application Scenarios
The DIN cast steel flanged Y-type filter is widely used in the following fields:
Chemical Industry: It is used to filter impurities in chemical raw materials, protect equipment such as reactors, pumps, and heat exchangers, and ensure the smooth progress of chemical production.
Petroleum Industry: In the processes of oil exploration, transportation and refining, it is used to remove solid particles in media such as crude oil and natural gas to prevent equipment blockages and damage.
Pharmaceutical Industry: It is used for fluid filtration in pharmaceutical production lines to ensure the purity and quality of drug production.
Food Processing Industry: It is used in production lines of beverages, beer, dairy products, etc., to filter impurities in fluids such as water and syrup, and ensure the safety and taste of food.
Energy Industry: In steam systems and hot water systems, it is used to filter impurities, protect equipment such as steam boilers and heat exchangers, and improve energy utilization efficiency.
Installation and Maintenance
Installation: During installation, it should be ensured that the flow direction of the filter is consistent with that of the fluid to avoid reverse installation. Meanwhile, check the sealing of the flange connections to ensure there is no leakage.
Maintenance: Regularly check the operating state of the filter. Depending on the cleanliness of the fluid and the frequency of use, regularly clean or replace the filter screen. When cleaning, appropriate cleaning agents should be used to avoid damaging the filter screen.
J-VALVES Note: All the data should be confirmed with the approved drawings of manufacturer.


Competitive Advantage:
On Samples Buyer bear the air fee, but this fee will be reduced from order directly
On After Sales Free replacement if there is any quality problem
On Delivery Never delay delivery time
On Materials Ensure material pure
Ensure material pure
Between the handle and the ball there are four fits. Which one shears, which one cracks, and how a few degrees of lost motion hides a valve that never seated.
Reverse flow through a check valve has six mechanical causes. How hinge wear, debris and a moved seat ring look different, and which test finds each.
Trapped-liquid overpressure in DBB/DIB ball valves: thermal expansion arithmetic, SPE vs DPE seats, external cavity relief valve setting and the fire case.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.