| Availability: | |
|---|---|
| Quantity: | |
900LB DBB Double Block Double Discharge Stainless Steel Flanged RF Floating Ball Valve
Product Features
Double block and double discharge function: The valve is designed with a double block function to ensure that the medium is completely isolated when in the closed state. It also has a discharge function, which can safely discharge the medium in the valve cavity.
High-pressure design: It is applicable to the 900LB pressure rating and can withstand high-pressure working conditions.
Stainless steel material: The valve body is made of 304 or 316 stainless steel materials, which have good corrosion resistance and high temperature resistance.
Flange connection: The flange connection method conforming to the ANSI B16.5 standard is adopted to ensure the firmness and sealing of the connection.
Floating ball design: The ball floats in the valve body and can automatically adapt to pressure changes to ensure the sealing performance.
Fireproof design: It complies with the API 607 fireproof standard to ensure that the sealing performance can still be maintained in extreme situations such as fires.
Anti-static design: Springs are installed between the valve body, the ball and the valve stem to prevent electrostatic accumulation and reduce the risks of fire and explosion.
Multiple operation modes: It is equipped with a manual operating mechanism, and gear transmission, electric or pneumatic actuators can also be optionally equipped.
Technical Parameters
Nominal diameter: 1/4"~8" (DN6~DN200)
Pressure rating: 150LB~1500LB (PN20~PN260)
Applicable temperature range: -29℃ ~ 150℃
Valve body material: 304 stainless steel, 316 stainless steel
Ball material: 316 stainless steel
Valve stem material: 316 stainless steel
Sealing material: PTFE, RPTFE, PPL
Connection method: Flange connection
Execution standards:
Design and manufacturing: API 6D
Testing standard: API 598
Flange standard: ANSI B16.5
Application Fields
Petroleum and natural gas industry: Used to control the flow of media such as natural gas and crude oil.
Chemical industry: Used to handle corrosive chemical media such as acids and alkalis.
Food and pharmaceutical industry: Used to handle liquid media in food and pharmaceutical production.
Urban gas pipeline network: Used to control the transportation of urban gas.
Water treatment and industrial facilities: Used to control the flow of media such as water and steam.
A knife gate valve has no seat pocket and no wedge: a beveled blade crosses the bore and cuts what is in it. Where it seals, where it cannot, what to order.
A Y type check valve puts the seat in a 45 degree branch and keeps the disc out of the bore. Orientation, cap access, failure points and what to specify.
Chlorine valve selection: the 150 ppm dry/wet divide, vapour pressure arithmetic, liquid-full cavity expansion to 390 bar, and proven relief paths.
Line pressure under the plug cancels axial thrust in a pressure balanced plug valve. What that buys in torque, what it costs, and how it fails silently.
Why oxygen valves burn: adiabatic compression arithmetic, EIGA velocity and exemption tables, PTFE limits and CGA G-4.1 cleaning rules.
What ASME and PED dual certification really requires: valve categories, modules, CE marking, material routes, the WCB Charpy trap and shipping documents.
Why a single disc wafer check valve lives inside the flange gap, what the line gasket does to its seat, which way to mount it, and what to order.
ASME B16.34 pressure-temperature ratings explained: material groups, the Class 150-2500 table, interpolation, Special Class limits and Class versus PN.
Why a T type strainer holds more screen than a Y type, where it belongs in the line, how the blowdown is used, and what to write on the enquiry.
Valve spare parts planning: failure data, interchangeable groups, Poisson stocking levels, kit contents, shelf life, lead times and repair vs replace.
Thermal growth eats the wedge guide clearance, the stem pushes the wedge into the seat, and packing tightens itself. What to check before blaming the valve.
Steam humidification guide: psychrometric load sizing, isothermal vs adiabatic, steam quality, control valve Kv selection, absorption distance limits.
Which parts of a gate, globe or check valve actually wear, what to keep on the shelf, and why a spare bought for the same size still will not fit.
Valve storage and preservation guide: ISO 2230 elastomer shelf life, nitrogen blanket storage, VCI protection, cycling schedules and RFQ clauses.
Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.Same size, same class, different length. Where the face-to-face number comes from, what to measure before ordering, and what a forced fit does to the joint.
What EN 10204 3.1 and 3.2 certificates prove for valve procurement: the stockist clause, PED category rules, PMA and heat number traceability checks.
A globe valve has a front and a back. Flow under the disc or over it decides where the pressure sits when shut, and which end of the stroke is hard.
Gear operator sizing from valve torque: breakaway vs running torque, MSS SP-91 handwheel force limits, MAST stem checks, ratio and turns arithmetic.
Stem up, sideways or down: what each does to the bonnet cavity and packing, plus correct orientation for swing checks, Y strainers and butterfly valves.
Class 125 is 13.8 bar and a ductile iron main can surge to 24. Why the body material decides whether a water valve cracks or bulges, with the arithmetic.