| Availability: | |
|---|---|
| Quantity: | |
API594 C95800 Bronze Dual Plate Wafer Check Valve
Technical Specifications
Design Standards: Complies with international standards such as API 594 and ASME B16.34.
Materials:
Valve Body: Aluminum Bronze (ASTM B148 C95800)
Valve Disc: Aluminum Bronze (ASTM B148 C95800)
Sealing Material: Usually VITON or other corrosion-resistant materials.
Size Range: 2" ~ 84" (DN50 ~ DN2100)
Pressure Rating: 150LB ~ 2500LB (PN20 ~ PN420)
Working Temperature: -20°F ~ 450°F (approximately -29°C ~ 232°C).
Connection Method: Wafer Type. Flanged Type or Lug Type can also be provided.
Sealing Performance: Complies with the API 598 testing standard.
Product Features
Double-Disc Structure: Adopting a double-valve disc design, it can quickly respond to the forward and reverse flow of fluid, ensuring reliable sealing performance.
Strong Corrosion Resistance: The Aluminum Bronze material has excellent seawater corrosion resistance, and is especially suitable for offshore engineering and the chemical industry.
Compact Design: The wafer connection method saves space and is convenient for installation and maintenance.
High-Efficiency Sealing: Metal-to-metal sealing is adopted between the valve disc and the valve seat to ensure zero leakage.
Quick Installation: The wafer connection method does not require flanges, making installation simple and saving time and cost.
Application Areas
Offshore Engineering: Used in seawater pipeline systems to prevent seawater backflow.
Chemical Industry: Suitable for the transportation of corrosive media such as acids, alkalis, and salts.
Water Treatment Systems: Used to prevent water backflow and protect pumps and pipeline systems.
Petroleum and Natural Gas Industry: Used for transporting media such as petroleum and natural gas to ensure the safe operation of pipeline systems.
Industrial Fluid Systems: Applicable to the control of various industrial fluids such as cooling water and steam.
Installation and Maintenance
Before Installation: Check whether the inside of the valve is clean and make sure there is no impurity blocking the valve disc. Check whether the connection parts are intact.
During Installation: Ensure that the fluid flow direction is consistent with the arrow mark on the valve body. When using the wafer connection method, make sure that the pipeline flanges are aligned with the valve and tighten the bolts evenly.
Maintenance: Regularly check the sealing performance of the valve. If there is leakage, replace the sealing parts in time. Regularly clean the impurities inside the valve body to ensure the normal operation of the valve.
Advantages
High-Quality Manufacturing: Manufactured strictly in accordance with API 594 and ASME B16.34 standards to ensure product quality and performance.
Customization Service: Customized products with different sizes, pressure ratings and materials can be provided according to customer needs.
Wide Application: Applicable to various media and working conditions to meet the needs of different industries.
API594 C95800 Bronze Dual Plate Wafer Check Valve
Technical Specifications
Design Standards: Complies with international standards such as API 594 and ASME B16.34.
Materials:
Valve Body: Aluminum Bronze (ASTM B148 C95800)
Valve Disc: Aluminum Bronze (ASTM B148 C95800)
Sealing Material: Usually VITON or other corrosion-resistant materials.
Size Range: 2" ~ 84" (DN50 ~ DN2100)
Pressure Rating: 150LB ~ 2500LB (PN20 ~ PN420)
Working Temperature: -20°F ~ 450°F (approximately -29°C ~ 232°C).
Connection Method: Wafer Type. Flanged Type or Lug Type can also be provided.
Sealing Performance: Complies with the API 598 testing standard.
Product Features
Double-Disc Structure: Adopting a double-valve disc design, it can quickly respond to the forward and reverse flow of fluid, ensuring reliable sealing performance.
Strong Corrosion Resistance: The Aluminum Bronze material has excellent seawater corrosion resistance, and is especially suitable for offshore engineering and the chemical industry.
Compact Design: The wafer connection method saves space and is convenient for installation and maintenance.
High-Efficiency Sealing: Metal-to-metal sealing is adopted between the valve disc and the valve seat to ensure zero leakage.
Quick Installation: The wafer connection method does not require flanges, making installation simple and saving time and cost.
Application Areas
Offshore Engineering: Used in seawater pipeline systems to prevent seawater backflow.
Chemical Industry: Suitable for the transportation of corrosive media such as acids, alkalis, and salts.
Water Treatment Systems: Used to prevent water backflow and protect pumps and pipeline systems.
Petroleum and Natural Gas Industry: Used for transporting media such as petroleum and natural gas to ensure the safe operation of pipeline systems.
Industrial Fluid Systems: Applicable to the control of various industrial fluids such as cooling water and steam.
Installation and Maintenance
Before Installation: Check whether the inside of the valve is clean and make sure there is no impurity blocking the valve disc. Check whether the connection parts are intact.
During Installation: Ensure that the fluid flow direction is consistent with the arrow mark on the valve body. When using the wafer connection method, make sure that the pipeline flanges are aligned with the valve and tighten the bolts evenly.
Maintenance: Regularly check the sealing performance of the valve. If there is leakage, replace the sealing parts in time. Regularly clean the impurities inside the valve body to ensure the normal operation of the valve.
Advantages
High-Quality Manufacturing: Manufactured strictly in accordance with API 594 and ASME B16.34 standards to ensure product quality and performance.
Customization Service: Customized products with different sizes, pressure ratings and materials can be provided according to customer needs.
Wide Application: Applicable to various media and working conditions to meet the needs of different industries.
In the realm of industrial fluid handling, stainless steel Y-type strainers stand as a cornerstone of system reliability, efficiency, and longevity. Engineered to remove debris, particles, and contaminants from pipelines, these devices play a pivotal role in safeguarding equipment, reducing downtime
Structure and Working Principle of Double Disc Bronze Check ValveThe double disc bronze check valve is mainly composed of a valve body, two half-disc valve discs, a hinge mechanism, and sealing surfaces. The discs are connected by hinges and installed inside the valve body, enabling them to automati
In industrial fluid systems, filters are critical components that ensure system cleanliness and prevent contaminants from entering. The J-VALVES 2" 600LB CF8M Y-Type Filter is a high-efficiency, reliable filtration solution suitable for a wide range of industrial applications.1. High Pressure Resist
In industrial production, high temperature working conditions impose extremely stringent requirements on the performance of equipment. Especially in the filtration process involving high-temperature fluids, it is crucial to choose the appropriate filter material and model. Y-type strainer made of nickel aluminum bronze B148 (C95800) material have become the first choice for many engineers due to their excellent high temperature resistance and corrosion resistance.
What is a B62 Bronze Gate Valve?The B62 Bronze Gate Valve is a type of gate valve designed for industrial use, primarily in fluid control systems. Constructed from Ni-Al bronze, it offers excellent resistance to corrosion, high temperature, and pressure, making it an ideal choice for demanding envir
In the field of shipbuilding, seawater filtration is an important link to ensure the normal operation of key systems of ships. As a high-performance seawater filtration device, the C95800 strainer has become an indispensable component in shipbuilding due to its outstanding corrosion resistance, high
What Are Gate Valves?A gate valve is a type of valve that uses a sliding gate to control the flow of fluid. The gate moves vertically within the valve body to open or close the passage. When fully open, the gate valve creates a straight path for the flow of fluids, allowing minimal pressure drop. Ga
In modern industrial fluid control systems, tiny impurities are often the "invisible killers" that cause costly equipment failures. Founded in 2009, J-VALVES has been committed to the R&D and manufacturing of industrial valve solutions. Among our products, the Y-Strainer has become a core component for protecting pumps, compressors, and instrumentation systems due to its exceptional filtration efficiency and durability.
Understanding J-VALVES High-Performance Gate ValvesJ-VALVES' high-performance gate valves are designed with advanced engineering principles to ensure they can withstand the rigors of industrial use. These valves are available in a variety of sizes, materials, and configurations, allowing them to be
Selection Guide(1) Selection Based on Fluid CharacteristicsLiquid: If the fluid is water or a low-viscosity liquid with few impurities, a Y-type strainer can be selected; if the fluid is oil or contains a large amount of impurities, it is recommended to choose a basket strainer.Gas: For gas filtrati
In process systems such as petrochemical, industrial water treatment, energy, power, and fine chemical industries, pipeline clogging due to impurities remains one of the core issues affecting stable system operation. Once welding slag, rust, sand particles, or solid debris enter the pipeline, they not only cause valve jamming and pump wear but may also lead to unplanned shutdowns, resulting in high maintenance costs.
In the world of industrial processing, pipeline integrity is paramount. Any contamination within pipelines can result in costly damage to machinery, reduced efficiency, and potential downtime. This is where Basket and Y-type strainers come into play, serving as critical filtration devices for a vari
Y-type strainerStructural DesignThe Y-type strainer is shaped like the letter "Y". It is mainly composed of nozzles, the main pipe, a strainer screen, flanges and fasteners. The strainer screen is installed inside the main pipe. After the fluid enters from the inlet, it is strainered through the str
In industrial pipeline systems, protecting critical equipment from solid contaminants is essential for long-term reliability and operational safety. This is where the J-VALVES basket strainer plays a vital role. Designed for high flow capacity and efficient particle removal, it is widely used across industries where fluid cleanliness directly impacts system performance.
Understanding Double Block-and-Bleed (DBB) Ball ValvesDBB ball valves are designed to provide two independent seals (one upstream and one downstream) and a bleed port to vent any trapped fluid between the seals. This design ensures that the valve can safely isolate a section of the pipeline and reli
I. Application of Y-Type Filters in Fine Chemicals(1) Structural and Performance Characteristics Y-type filters are named for their shape resembling the letter "Y". They are mainly composed of connecting pipes, main pipes, filter screens, flanges and fasteners. Its filter screen is usually made of s
To our valued clients:On this cozy Christmas season, the J-VALVES team sends you warmest wishes—may your holidays be filled with joyful laughter, your ongoing projects run smoothly with efficiency, and the coming year bring more fruitful & win-win collaborations between us.J-VALVES specializes in pr
In industrial fluid systems, strainers are often not the most eye-catching equipment, but they are critical components that determine system stability and equipment lifespan. As can be seen from the images, J-VALVES Basket / Y-Type Strainers feature a striking red heavy-duty valve body design with a compact structure and clearly visible filtration elements, fully embodying their reliable positioning in industrial-grade applications.
Why Do Many Industrial Systems Still Suffer From Unexpected Pressure Drop and Blockage?<br /> <br /> In many industrial piping systems, Y strainers are considered “basic components” — simple, reliable, and easy to install. However, in real-world operation, engineers and maintenance teams often encounter recurring issues that lead to pressure loss, frequent shutdowns, and even downstream equipment damage.
When it comes to ensuring the efficiency and longevity of fluid systems, the selection of strainers plays a pivotal role. Two of the most commonly used types are Basket Strainers and Y-Type Strainers, both of which are designed to filter out debris and impurities from the fluid. Each type has distin