| Availability: | |
|---|---|
| Quantity: | |
API594 C95800 Bronze Dual Plate Wafer Check Valve
Technical Specifications
Design Standards: Complies with international standards such as API 594 and ASME B16.34.
Materials:
Valve Body: Aluminum Bronze (ASTM B148 C95800)
Valve Disc: Aluminum Bronze (ASTM B148 C95800)
Sealing Material: Usually VITON or other corrosion-resistant materials.
Size Range: 2" ~ 84" (DN50 ~ DN2100)
Pressure Rating: 150LB ~ 2500LB (PN20 ~ PN420)
Working Temperature: -20°F ~ 450°F (approximately -29°C ~ 232°C).
Connection Method: Wafer Type. Flanged Type or Lug Type can also be provided.
Sealing Performance: Complies with the API 598 testing standard.
Product Features
Double-Disc Structure: Adopting a double-valve disc design, it can quickly respond to the forward and reverse flow of fluid, ensuring reliable sealing performance.
Strong Corrosion Resistance: The Aluminum Bronze material has excellent seawater corrosion resistance, and is especially suitable for offshore engineering and the chemical industry.
Compact Design: The wafer connection method saves space and is convenient for installation and maintenance.
High-Efficiency Sealing: Metal-to-metal sealing is adopted between the valve disc and the valve seat to ensure zero leakage.
Quick Installation: The wafer connection method does not require flanges, making installation simple and saving time and cost.
Application Areas
Offshore Engineering: Used in seawater pipeline systems to prevent seawater backflow.
Chemical Industry: Suitable for the transportation of corrosive media such as acids, alkalis, and salts.
Water Treatment Systems: Used to prevent water backflow and protect pumps and pipeline systems.
Petroleum and Natural Gas Industry: Used for transporting media such as petroleum and natural gas to ensure the safe operation of pipeline systems.
Industrial Fluid Systems: Applicable to the control of various industrial fluids such as cooling water and steam.
Installation and Maintenance
Before Installation: Check whether the inside of the valve is clean and make sure there is no impurity blocking the valve disc. Check whether the connection parts are intact.
During Installation: Ensure that the fluid flow direction is consistent with the arrow mark on the valve body. When using the wafer connection method, make sure that the pipeline flanges are aligned with the valve and tighten the bolts evenly.
Maintenance: Regularly check the sealing performance of the valve. If there is leakage, replace the sealing parts in time. Regularly clean the impurities inside the valve body to ensure the normal operation of the valve.
Advantages
High-Quality Manufacturing: Manufactured strictly in accordance with API 594 and ASME B16.34 standards to ensure product quality and performance.
Customization Service: Customized products with different sizes, pressure ratings and materials can be provided according to customer needs.
Wide Application: Applicable to various media and working conditions to meet the needs of different industries.
API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.
ISO 5208 Rates A-G explained with real numbers, how API 598, API 6D and FCI 70-2 map across, and what metal seats can honestly achieve.
How to choose a forged or cast valve body: API 600 vs API 602 size limits, casting quality factor, NDT coverage, weld repair policy and cost crossovers.
How pressure seal bonnet valves work, why bolted bonnets stop at Class 900, seal ring materials, disassembly rules and the low-pressure leak signature.