| Availability: | |
|---|---|
| Quantity: | |
Main Features
Three-Piece Structure: The valve body adopts a three-piece design, facilitating installation and maintenance while ensuring the structural strength and sealing performance of the valve.
Fixed Ball Design: The ball is fixed by a rotating shaft, reducing operating torque and ensuring stability under high-pressure conditions.
Gear Operation: Equipped with a gear operating mechanism, it provides smooth and reliable operation, suitable for working conditions requiring frequent operation.
Fire-Safe Design: Complies with API 607 fire safety standards, ensuring sealing performance is maintained even in extreme situations such as fires.
Anti-Static Design: Prevents static accumulation caused by medium flow, improving safety.
Dual Sealing: Equipped with bidirectional sealing function, ensuring reliable prevention of medium backflow in both positive and negative directions.
Emergency Seal Greasing: When the seal is damaged, sealant can be injected through the greasing device to temporarily restore sealing performance.
Multiple Material Options: The valve body and ball can be made of carbon steel, stainless steel, and other materials to adapt to different media and working conditions.
Technical Specifications
Nominal Diameter: 2 inches to 48 inches (DN50 to DN1200)
Pressure Rating: 150LB to 2500LB (PN2.5 to PN42.0)
Applicable Media: Petroleum, natural gas, water, steam, air, oil products, etc.
Applicable Temperature: -46℃ to 500℃ (the temperature range may vary depending on the sealing material)
Valve Body Material: Forged steel (A105, A182 F304, F316, etc.)
Sealing Material: PTFE, PEEK, nylon, etc.
Connection Methods: Flange connection (ANSI B16.5, ASME B16.47), welded connection (ASME B16.25)
Design and Manufacturing Standards: API 6D, ANSI B16.34
Testing Standards: API 598, API 607
schematic diagram:

2.API6D Forged Steel 3PC Trunnion Ball Valve With Gear Operation Main dimensions&Weight:

API 598 test durations by size, why the timer starts after the pressure settles, and what a 1.5 times shell test cannot tell you about service.
Pneumatic actuator failure modes and field diagnostics: air supply quality, diaphragm rupture, spring relaxation, torque margins and partial stroke testing.
How a butterfly valve disc is fixed to its stem: taper pins, pinless hubs and through shafts, the backlash each allows, and the failures they cause.
Steam PRV station design: critical pressure ratio, Kv sizing, 1/3-2/3 parallel turndown, series stations and safety valve sizing rules.
Why LNG ball valve seats that pass warm tests leak cold at -162°C: contraction arithmetic, cold preload, PCTFE vs PTFE, ISO 28921-2 and MSS SP-134 limits.
What API 607 proves: burn sequence, 7th-edition leak limits per NPS, cavity pressure rules, API 6FA vs ISO 10497, and the clauses buyers must check.
MSS SP-80 bronze valves: the class number is a saturated steam rating, not a pressure rating. Alloys, threads, lead-free rules and where bronze stops.
Stellite or tungsten carbide for erosive service: erosion angles, hardness ratios, HVOF vs weld overlay, the 500 C limit, and the clauses that win acceptance.
Valve coating is a defect-budget decision, not a product choice: ENP vs FBE vs sprayed aluminium, holiday arithmetic, CUI and the specs that win acceptance.
Temporary and start-up strainers for commissioning: placement, plate versus mesh, blowdown discipline and the removal record that proves it was pulled.
What MSS SP-25 marking really commits to: body symbols, three-symbol trim marking, melt identification and the certificate that closes the loop.
Why ball valves pass high-pressure seat tests and fail at 0.6 MPa: seat preload arithmetic, SPE and DPE seats, DBB vs DIB-1/DIB-2, and test-proofing specs.
RF, RTJ and butt-weld valve ends compared: how each joint seals, which duty suits it, and the four assembly errors that cause most joint leaks.
Why PTFE and PFA liners fail when the chemistry is right: permeation arithmetic, vacuum collapse, cold flow and the 11:1 expansion mismatch at the flange.
C95800 and C95500 are cast to ASTM B148; C63200 is wrought to ASTM B150. Aluminum and manganese levels decide strength, weldability and valve use.
Jacket heat load arithmetic, sulfur's 159 C viscosity trap, the separate jacket pressure test and the weld failures buyers discover in year five.
API 603 and API 600 both cover bolted bonnet gate valves, but wall thickness basis, class ceiling and casting rules decide which one you can actually buy.
ISO 5208 Rates A-G explained with real numbers, how API 598, API 6D and FCI 70-2 map across, and what metal seats can honestly achieve.
How to choose a forged or cast valve body: API 600 vs API 602 size limits, casting quality factor, NDT coverage, weld repair policy and cost crossovers.
How pressure seal bonnet valves work, why bolted bonnets stop at Class 900, seal ring materials, disassembly rules and the low-pressure leak signature.