Regulating ValveYour Location:homeRegulating Valve

Electronic electric three-way control valve

Product DescriptionElectric Three Way(3-way) Diverting Control Valve (GZDLX) Characteristics:Electric Three Way Control Valve includes Electric Three Way Mixing Control Valve (GZDLQ) and Electric Three Way Diverting Control Valve (GZDLX). Mixing Control Valve is mainly used to mix the medium...
Payment protection On-time shipment Product quality protection
Payment:
  • Electronic electric three-way control valve

Product Description

Electric Three Way(3-way) Diverting Control Valve (GZDLX) Characteristics:
Electric Three Way Control Valve includes Electric Three Way Mixing Control Valve (GZDLQ) and Electric Three Way Diverting Control Valve (GZDLX). Mixing Control Valve is mainly used to mix the medium from 2 different ports and let it flow out through the third port. Diverting Control Valve is to separate the medium from one port and let it diverted flowing out through the other 2 ports. When the Valve size is small and pressure differential is small, Mixing Control Valve can also be used as Diverting Control Valve. But if the valve size is big and pressure drop is big, both can not be replaced each other.


Standard technical specification
Valve Body
Type:  ZDLQ--Three Way Mixing Control Valve,  ZDLX---Three Way Diverting Control Valve
Size: DN25-300
Pressure: PN16~PN40, Class 150LB ~ Class 300LB
Connection: RF(Standard), Threaded, Welded
Flange Facing:  Raised Face
Face to Face dimension: GB12221-89
Material: WCB, 304,316
Bonnet Type: Gland
Packing:  V tupe PTFE,  Flexible Graphite
Gasket: Plain Type, PTFE, SS+Graphite
 
Valve Trim
Disc: Three Way Linear Type or V Type
 
Actuator
Type: Electric Actuator
Model: 381LSA/XA-08,  381LSA/XA-20,  381LSB/XB-30,  381LSB/XB-50, 381LSC-65, 381LSC-99
381LSC-160, 381LSC-260
Valve Action: Direct Action, Reaction (Force)
Controlling Action: Proportional Linear Controlling or ON-OFF Controlling.
Input Signal: 4~20mA DC or 1~5V DC
Power: AC220V, 50HZ
Output Signal: 4~20mA DC
Power Consumption: A Type-50VA, B Type--150VA, C Type-220VA
Protection Level: IP55
Wire Connection: Normal S Type--G1/2", Explosion-Proof X Type---G3/4"
Ambient Temperature: Normal---10 Deg C~ 60 Deg C, With Space Heater---35 Deg C~ 60Deg C, Explosion-Proof X Type--- -10Deg C ~40 Deg C
Ambient Humidity: Normal S Type--Below 95%, Explosion-Proof X type--45%-85%
Explosion-Proof: ExdIIBT4
 
Performance
Raded KV Value: Refer to Table 1
Flowing Features: Linear
Adjusting Range: 30:1
Leakage Rate: Metal Sealing should be below 0.01% ANSI B16.104-1976 Class IV
            Soft Sealing should be below 0.00001% ANSIB16.104-1976  Class VI

Allowable Deviation: 1%


Your name
Your E-mail
Content